background image

1

C

L

1.50 DIA.

POWER

CORD 

HOLE

 

 7.50

  [190.5]

 

 3.50

  [88.9]

 

 3.50

  [88.9]

 

 3.50

  [88.9]

 

 1.68

   [42.6]

 

 1.00

   [25.4]

(10) .312 DIA. HOLES

 

  6.87

   [174.4]

 

  .81

   [20.5]

 

 10.25

  [260.3]

 

 8.00

  [203.2]

 

 7.81

  [198.3]

 

 1.82

  [46.2]

 

 1.18

  [29.9]

 

 6.50

  [165.1]

 

 5.25

  [133.3]

 

   6.16

    [156.4]

 

   8.50

    [215.9]

 

   20.00

    [508.0]

FILTER

 10.00

 [254.0]

 20.00

 [508.0]

 10.00

 [254.0]

 10.25

 [260.3]

POWER
CORD

M/TAB

DRAIN

(6) #10-32 WELD NUTS

THERMOSTAT 
ADJUSTMENT
ACCESS

(6) .312 DIA. HOLES

 

 15.31

  [388.8]

 

 14.81

  [376.1]

 

 .25

  [6.3]

 

 2.75

  [69.8]

 

 2.75

  [69.8]

 

 2.18

  [55.3]

 

 6.56

  [166.6]

 

 15.87

  [403.0]

 

 6.06

  [153.9]

 

 3.81

  [96.7]

 

 1.06

  [26.9]

 

 .75

  [19.0]

 

 6.00

  [152.4]

  TYP.

 

 2.00

  [50.8]

 14.31

 [363.4]

 15.87

 [403.0]

 15.93

 [404.6]

 10.62

 [269.7]

POWER
CORD

FILTER

DRAIN

THERMOSTAT 
ADJUSTMENT
ACCESS

1

 

 4.00

  [101.6]

 

 1.50

  [38.1]

 

 8.00

  [203.2]

 

 4.50

  [114.3]

 

 1.00

   [25.4]

 

 1.00

   [25.4]

 

 4.50

  [114.3]

 

 4.31

  [109.4]

 

 2.75

  [69.8]

 

 .81

  [20.5]

 

 12.87

  [326.8]

 

 4.43

  [112.5]

 

 4.87

  [123.6]

 

 .25

  [6.3]

 

 14.12

  [358.6]

 

 13.62

  [345.9]

(4)

.312 DIA.

HOLES

1.50 DIA.

POWER

CORD HOLE

 13.25

 [336.5]

 12.87

 [326.8]

 6.25

 [158.7]

 14.12

 [358.6]

THERMOSTAT 
ADJUSTMENT
ACCESS

POWER
CORD

DRAIN

FILTER

Drawings and Dimensions

Narrow-Mini

Micro-Mini

Dimensions (inches) are for reference only and are subject to change.

Super-Mini

MOUNTING PLANS

Micro-Mini

Super-Mini

Narrow-Mini

8

FILTERED CONDENSER
AIR INLET (Ambient Air In)

CONDENSER OUTLET
(Warm Ambient Air Out)

WARM AIR RETURN FROM
ENCLOSURE

COOL AIR OUTLET 
TO ENCLOSURE

1

2

3

4

Содержание K2A4C1.0MML

Страница 1: ...RTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 036 00 Find additional info...

Страница 2: ...age of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all si...

Страница 3: ...s prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connectio...

Страница 4: ...Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to th...

Страница 5: ...ession refrigeration cycle This takes place in a hermetically sealed refrigeration system utilizing either an air cooled or water cooled condenser heat exchanger The warm air inside the enclosure is d...

Страница 6: ...blower will be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evap...

Страница 7: ...nditioner Also be certain that when the door is opened fully the cabinet does not become unbalanced The actual weight of the unit can be found on page 9 Mounting Narrow Mini 1 See Page 8 for proper Mo...

Страница 8: ...363 4 15 87 403 0 15 93 404 6 10 62 269 7 POWER CORD FILTER DRAIN THERMOSTAT ADJUSTMENT ACCESS 1 4 00 101 6 1 50 38 1 8 00 203 2 4 50 114 3 1 00 25 4 1 00 25 4 4 50 114 3 4 31 109 4 2 75 69 8 81 20 5...

Страница 9: ...7 1 58 KA4C2 0SML56 2000 115 50 115M 50 60 7 1 58 K2A4C2 0SML 2000 115 50 230 200 60 50 3 5 58 K2A4C2 0SML5 2000 115 50 230 50 3 2 58 Narrow Mini Series KA4C1 0NML 1000 125 50 115 100 60 50 7 1 53 KA4...

Страница 10: ...ressor 0665 100 0665 102 0665 102 Condenser Blower Motor 0265 03 0261 08 0265 03 Condenser Blower Motor Capacitor N A 0452 03 N A Condenser Blower Assembly N A 7090 00 17 N A Evaporator Blower Motor 0...

Страница 11: ...nd the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic A...

Страница 12: ...ypass valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect...

Страница 13: ...applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Application Failed Evaporator Blower Replace Evaporator Blower Mo...

Страница 14: ...ived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a suit...