Koolbreeze DKB100L Скачать руководство пользователя страница 3

Instructions of keys

1

ON/OFF

press ON/OFF, the unit runs in a circulation “ON-OFF-ON”

2

Humidity up and down: press “humidity up or down” once and the set humidity will increase or decrease by 1%.

Press the key for 1.5 seconds and the set value will increase or decrease by 1%. Pressing continuously with
change the indicator 5 points per second.

3: Timer: press the timer key, the window will show”0” press the key again, it will show “1” Press continuously, it
will show “2,3,4,….8” press again, it will be “0” Timer indicator will light if the timer function is on. The window
will change to humidity indicator 5 seconds after the timer is set.

Starting the Unit

1: Plug in and turn on at the mains ; the unit gives off a “ding sound”
2: Press ON/OFF, the running indicator light comes on and the humidity display window light comes on .Initially it

displays the previously set humidity, the initial humidity setting is 60% and 3 seconds later, the humidity display
window lights to display the current humidity.

3: Press humidity up or down key to adjust the humidity needed, If the set humidity is 3% less than current the

humidity, the unit runs, If the set humidity is 3% more than current humidity, the unit stops running.

4: If set humidity is less than 30%, the unit stops running.

Turning the Unit Off.

Press ON/OFF when the unit is running, the unit stops running and all indicators go off.

Caution:

1: when the set humidity is higher than current humidity, the unit will not run..
2: When the tank is full, the tank full indicator lights and the compressor and the fan motor shut off automatically,

and the buzzer gives off a “ding ding”sound. This sound will last ten times. Only after emptying the tank the
tank full indicator will the tank full light go off and the unit willrun again when the ON/OFF is pressed.

3

When dehumidifying, the fan motor and compressor must be running at least for 3 minutes. Once the

compressor starts, DO NOT restart the compressor again within 3 minutes of the unit shuttting off. To do so can

cause severe damage

to the unit

4

When operating in low temperature, the unit judges the system temperature automatically to decide when to

defrost. When defrosting, the defrosting indicator lights on, the fan motor runs but the compressor shuts off
automatically.

5

The humidity display window shows humidity from 30% to 90%.

6

Keep the unit unplugged if not used for a long time

Timer

Tank full

Indicator window

Defrosting

Operation

Timer setting

Humidity UP

Humidity down

ON/OFF

Отзывы: