background image

7

6

User Manual

Display Panel

The Koolance display panel allows control and monitoring of various aspects of 

the cooling unit. 5 buttons are used, with directional arrows to navigate or change 

settings, and a center button to select/exit.

Navigate Up,

Increase Setting

Navigate Down,

Decrease Setting

Navigate 

Left

Navigate 

Right

Enter/Exit

Software Control

This unit supports Koolance’s “System Monitor” application for device control, 

viewing, and logging data to a computer file. Visit www.koolance.com/software to 

download the latest version of the program. Consult the application’s readme.txt 

for details on usage. Software features requires the USB port be connected to a 

computer running Windows 10.

    • On the main screen, hold 

 for 3 seconds to change display units between 

      °C/°F and LPM/GPM.

12V/24V Pump Jumper

Select between a maximum pump output voltage of 12VDC or 

24VDC by moving the indicated jumper. ONLY USE A VOLTAGE 

SUPPORTED BY THE CONNECTED PUMP, or damage can occur.

External Sensors

Up to two K-type thermocouples and one Koolance 

10K Ohm thermistor (sensors not included) can be 

used for temperature monitoring, alarm, and relay 

options. For thermocouples, follow the polarity 

marked on the board.

Thermocouples

(x2)

Thermistor

(x1)

TEMP/FAN SET

Under “TEMP/FAN SET”, you can select an active set-point temperature the 

controller will attempt to follow by way of automatically adjusting fan speed. It is 

also possible to keep the fans at a fixed power level. There are four options to 

select from. 

Press 

▼ and ▲ 

to scroll among them:

    LIQ TEMP

:  Thermistor Temperature (Range: -30 to 90°C)

    CH1 TEMP

:  Thermocouple #1 Temperature (Range: -20 to 120°C)

    CH2 TEMP

:  Thermocouple #2 Temperature (Range: -20 to 120°C)

    FAN PWR

:  Static fan power setting (Range: 0 to 100%)

The sensor currently displayed in this menu is what the unit will follow.

 Only 

one can be active. 

Press 

 to adjust the target value using ▼ and ▲. Below are 

some examples:

  LIQ TEMP= 32C  

Maintain thermistor sensor at 32°C

  CH1 TEMP= 50C  

Maintain the first thermocouple at 50°C

  CH2 TEMP= -5C  

Maintain the second thermocouple at -5°C.

  FAN PWR= 45%  

Keep fans at 45% power, regardless of temperature.

Press

 

 

again to exit configuration of the sensor. Press ◄ to return to the previous 

menu.

Main Menu

To enter the main menu, briefly press 

. The selected option will begin flashing. 

Use ▼ and ▲ to navigate this menu.

    TEMP/FAN SET

:  Temperature set-point and fan settings

    ALARM SET

:  Alarm settings

    RELAY SET

:  Relay Trigger settings

    PUMP SET

:  Pump speed settings

    FLOW SET

:  Flow meter settings

    DISPLAY SET

:  LED display settings

When in the top menu, press 

 to enter one of the above categories. To exit from 

here and most subcategories, press ◄.

12V

Max

24V

Max

    • You can exit any menu and return to the main screen by holding 

 

for 2 

       seconds.

    • To reset 

ALL

 settings to default, hold ▼ + ▲ for 3 seconds.

To power on the unit, flip the front power switch.

Содержание CTR-KSM100

Страница 1: ...Superior Liquid Cooling Systems English v1 0 www koolance com ISO 9001 Printed in Korea CTR KSM100 User s Manual CTR KSM100 User s Manual ...

Страница 2: ...ration control life support or weapon launching control If these products are used in such hazardous environments Koolance Incorporated does not warrant them TRADEMARKS The Koolance name and logo are trademarks or registered trademarks of Koolance Inc Other company and product names used in this publication are for identification purposes only and may be trademarks or registered trademarks of thei...

Страница 3: ...t Improper power can damage the unit and is not covered under the warranty CAUTION Do not power 12V pump using the 24V maximum jumper setting This can permanently damage the pump and or the product and is not covered under the warranty KOOLANCE CONTACT INFORMATION Koolance Inc USA Address 2840 W Valley Hwy N Ste 101 Auburn WA 98001 USA Telephone 01 253 249 7669 Technical Support tech koolance com ...

Страница 4: ...s not supported Temperature Sensors One Koolance 10K ohm thermistor and up to two K type thermocouples are supported Flow Meter One Koolance flow meter can be connected to the unit Models INS FM14 INS FM16 INS FM17 N INS FM18 INS FM19 and SEN FM18T10 are supported Coolant Level Sensor One Koolance reservoir level sensor can be connected to the unit Models SEN LVL70 and SEN LVLIR01 are supported Mo...

Страница 5: ...e the controller will attempt to follow by way of automatically adjusting fan speed It is also possible to keep the fans at a fixed power level There are four options to select from Press and to scroll among them LIQ TEMP Thermistor Temperature Range 30 to 90 C CH1 TEMP Thermocouple 1 Temperature Range 20 to 120 C CH2 TEMP Thermocouple 2 Temperature Range 20 to 120 C FAN PWR Static fan power setti...

Страница 6: ...to 10 000LPM FLOW Coolant Flow Rate Range 0 1 to 10 0LPM LEVEL Low Coolant Level in Reservoir ON or OFF to disable If CYCLIC is chosen from the DISPLAY SET menu multiple values can be rotated through the front display The first line will flash Use and to navigate to other lines Press to enable or disable each value This will remove the asterisk thereby hiding that line from being shown on the main...

Страница 7: ...air or replace any defective Koolance system without charge Shipping costs are non refundable This warranty is non transferable All warranty claims must be accompanied by the original proof of purchase THIS WARRANTY DOES NOT COVER DAMAGE RESULTING FROM ACCIDENT MISUSE OR ABUSE LACK OF REASONABLE CARE SHIPPING DAMAGE MODIFICATIONS THE AFFIXING OF ANY ATTACHMENT NOT PROVIDED WITH THE PRODUCT LOSS OF...

Отзывы: