6.  Waste disposal in accordance with legal provisions 

After the phase of use the last proprietor is responsible for the adequate waste manage-
ment. The environmental regulations in the exporting country must be observed.

 

The following list contains the most important regulating literature, valid for the 

Federal Rep. of 

Germany

  Resolution for dangerous substances 

  Law for waste circulation (KRW/AfgG)) 

  Resolution for the proofs of utilization and 

removal 

  Criminal Code (StGB) 28th section „criminal 

acts against the environment” §326 - En-
vironment jeopardizing waste management 

  Law of chemicals § 27 - penal prescriptions 

  Resolution for used oil 

  Law of water balance 

  Resolution for the waste management of old 

cars and the adaptation of road prescriptions 

  Resolution (EC) No. 2037/2000 of the Euro-

pean Parliament and of the Council for ma-
terials that affect the ozone layer 

  Resolution to prohibit certain ozone destroy-

ing halogen hydrocarbons. 

The used refrigerant endangers the environment. When dealing with refrigerants the existing pre-
scriptions and regulations are to be followed. 

Only qualified staff is allowed to carry out these 

works! 

Water endangering substances - acc. to §§19g-19l - are solid, liquid, and gaseous substances. 
e.g.: mineral and tar oils (cooling oils), halogen containing organic combinations (refrigerants). 

  

Source of supply: 

Bundesanzeiger 

Beuth Verlag 

dtv (Deutscher Taschenbuch Verlag

 

 
 

7.  History of modification 

Version  Date 

Name 

Remark 

File 

A00 

08.03.2016   B Keßler  Source file 

BAKL481602A 

A01 

13.07.2016  B. Keßler  Added KL47T and KL49T 

BAKL481602A 

A02 

01.03.2017  B. Keßler  Information on the operating instructions and 

technical data expanded with F-gas-regulation 

BAKL481602A 

 

Содержание KL47T

Страница 1: ...adt Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA air conditioning unit KL47T KL48T KL49T with control KS600 CAN Version 24 Volt DC Frischluft Heizung ID BBA KL481602A Version A02 ...

Страница 2: ...t 5 1 2 Intended use 6 1 3 Operating conditions 6 3 Operation 6 1 4 Operation panel function of the keys 6 1 5 Special functions of the KS600 8 4 Maintenance 9 1 6 Compressor type KVX 10 1 7 Return air grid 10 1 8 Condenser coil 10 1 9 Troubleshooting 10 5 Warranty Conditions 10 6 Waste disposal in accordance with legal provisions 11 7 History of modification 11 Appendix Maintenance Schedule Bus W...

Страница 3: ...ncreases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any w...

Страница 4: ... is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above notes I...

Страница 5: ...rand quantity liter Esteröl SE55 2 liter Magnetic clutch 1 weight approx kg 12 24V DC 12 kg 1 ø depending on vehicle type 2 Generally information for a c unit Attention in case of roof top a c units Never switch on the a c unit during car wash The a c unit is operational with running engine only At cooling operation the humidity inside the vehicle is decreased which avoids steamed up windows The a...

Страница 6: ...sion nor for consequential damage resulting there from nor for damages caused by cleaning the systems with highly compressed or corrosion advancing substances 3 Operation Danger of accidents Focussing your attention on the road traffic is of top priority Only operate your air conditioning unit when the traffic situation allows it Make sure you can clearly recognize and read all operation and displ...

Страница 7: ...eat to recirculation Long press Double click Key combination Keypress Functional description Short press Turns ECO AUTO without compressor ON and OFF Long press Double click Key combination Keypress Functional description Short press Turns Automatic ON and OFF Long press Can be switched between AUTO HEAT COOL Double click Key combination You get into the service modus Ignition OFF Querying the err...

Страница 8: ...teps Long press Double click Key combination Keypress Functional description Short press Reducing the room set temperature for the passenger compart ment After reaching the minimum Temperature 6 x press key MAX COOL Long press Double click Key combination Keypress Functional description Short press Switches the auxiliary heater ON Long press Double click Key combination Ignition OFF Preheater star...

Страница 9: ...r dates for maintenance works and services with a KONVEKTA service sta tion as indicated in maintenance schedule bus no WP07050618 On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Only qualified staff is allowed to carry out these works For general instructions on repair and maintenance works please con...

Страница 10: ...efective check electric connections at switchboard defrost thermostat has switched off check relay replace if necessary outside temperature too low possible icing of evaporator check evaporator blower replace if necessary evaporator coil dirty switch on ventilation only compressor does not compress clean evaporator coil with compressed air excess pressure pressure too high check pressure at suctio...

Страница 11: ...ation of road prescriptions Resolution EC No 2037 2000 of the Euro pean Parliament and of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out...

Отзывы: