8. 

Waste disposal in accordance with legal provisions 

After the phase of use the last proprietor is responsible for the adequate waste management. 
The environmental regulations in the exporting country must be observed.

 

The following list contains the most important regulating literature, valid for the 

Federal Rep. of 

Germany

  Resolution for dangerous substances 

  Law for waste circulation (KRW/AfgG)) 

  Resolution  for  the  proofs  of  utilization  and 

removal 

  Criminal  Code  (StGB)  28th  section  „criminal 

acts  against  the  environment”  §326  -  En-
vironment jeopardizing waste management 

  Law of chemicals § 27 - penal prescriptions 

  Resolution for used oil 

  Law of water balance 

  Resolution  for  the  waste  management  of  old 

cars and the adaptation of road prescriptions 

  Resolution  (EC)  No.  2037/2000  of  the  Euro-

pean Parliament and of the Council for mate-
rials that affect the ozone layer 

  Resolution  to  prohibit  certain  ozone  destroy-

ing halogen hydrocarbons. 

The used refrigerant endangers the environment. When dealing with refrigerants the existing pre-
scriptions and regulations are to be followed.

 Only qualified staff is allowed to carry out these 

works! 

Water endangering substances - acc. to §§19g-19l - are solid, liquid, and gaseous substances. e.g.: 
mineral and tar oils (cooling oils), halogen containing organic combinations (refrigerants). 
 

  

Source of supply: 

Bundesanzeiger 

Beuth Verlag 

dtv (Deutscher Taschenbuch Verlag

 

 

9. 

History of modification 

Version  Date 

Name 

Remark 

File 

A00 

12.03.2007  S. Pfluger  source file 

BAKL40T12AA 

A01 

09.07.2007  B.Keßler 

Added KL45T and technical data  

BAKL40T12AA 

A02 

24.10.2007  B.Keßler 

Added item 1 and 1.1 “important”  

BAKL40T12AA 

A03 

18.03.2009  B. Keßler 

Pkt.1.2 updated; TM31 replaced by HDC 33 

BAKL40T12AA 

A04 

21.06.2016  B. Keßler 

Manual expanded and updated by KL46 

BAKL40T12AA 

A05 

02.03.2017  B. Keßler 

Information on the operating instructions and 
technical data expanded with F-gas-regulation 

BAKL40T12AA 

 

Содержание KL40T/12V

Страница 1: ...many 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA Air Conditioning unit KL40T KL45T KL46T with control KS60 Versions 12 24 Volt DC Recirculated Air Fresh Air Heating ID BBA KL40T12AA Version A05 ...

Страница 2: ...of a c system 8 5 3 Adjustment of temperature 8 5 4 Recirc Air operation only in case of a c units with Rec air flaps option 8 5 5 REHEAT activate stop 8 5 6 Display of air duct temperature 8 5 7 Indicate outside temperature only in case of a c units with heating option 9 6 Maintenance Servicing 9 6 1 Oil change Compressor type KVX 9 6 2 Return air grid 9 6 3 Condenser coil 9 6 4 Troubleshooting 1...

Страница 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Страница 4: ... In case your product is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged...

Страница 5: ...rd fans and or blowers 1 1 Compressors Important To avoid leakages at the shaft seal of the compressor The compressor should be started every 4 weeks for approx 15 minutes This also applies when the vehicle is not into operation for a longer period or when the air conditioning unit is not used Compressor type depending on scope of delivery see identification plate at compressor Compressor Type KVX...

Страница 6: ...e environmental conditions i e air containing salt phosphate or ammoniac extremely a corrosion of the cupper and aluminium components can not be ruled out The cupper and aluminium components of the KONVEKTA systems are not suitable for such extreme application conditions We indicate emphati cally that corrosion is not subject to warranties for defects KONVEKTA does not take over any war ranties fo...

Страница 7: ...all displays against irritating sunglare and any other optical disturbances Please note that the control panel keys have not been designed for heavy stressing Excessive or fast pressing of the keys for adjusting the set temperature does not accelerate the cooling down process It possibly damages the control panel and so affects the general perfor mance of the air conditioning unit 5 1 Operation pa...

Страница 8: ...o interior room of the vehicle see 4 Start of the recirculated air operation Press key S6 the LED display will light up This position should not be adjusted very long If windows are misting up return air operation should be switched off If key S6 is pressed again the return air flap will be reactivated and fresh air operation restarted The LED display will go out Automatic In case of a temperature...

Страница 9: ...r operational reliability We recommend having all works and modifications carried out at an authorized KONVEKTA Service Station Before carrying out any maintenance works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all ...

Страница 10: ...ck fuses at switchboard clean condenser coil with compressed air LED flashes up excess pressure caused by high outside temperature run unit until pressure has stabilized leakage in a c unit lack of refriger ant check a c unit for leakages refill refrigerant low pressure dryer clogged replace dryer low pressure screen of expansion valve clogged clean screen replace dryer compressor does not compres...

Страница 11: ...als that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and gaseous substances e g mineral and ...

Отзывы: