BAKL30T12AD 

Edition: 28.02.2017

 

Page: 7/14

 

 

4.2. 

Demounting 

1.  Open the accordant cover in the dash board to get access to the back side of the controller. 
2.  Press the mounting brackets together, either by hand or with a tool, and push the controller for-

ward. 

3.  Take off the plug and remove the controller. 

5.  Operation 

   

Danger of accident!

 

 

Focussing your attention on the road traffic is of top priority 

 

Only operate your air conditioning unit when the traffic situation allows it  

 

Make sure you can clearly recognize and read all operation- and display-elements at any time 

 

Protect all displays against irritating sunglare and any other optical disturbances 

 

Please note that the control panel keys have not been designed for heavy stressing  

  Excessive or fast pressing of the keys for adjusting the set temperature does not accelerate the 

cooling  down  process.  It  possibly  damages  the  control  panel  and  so  affects  the  general  perfor-
mance of the air conditioning unit. 

5.1.  Description of the display (LCD symbols) 

 
 
 
 
 
 
 
 
 
 
 

Symbol 

Acceptation of the display symbols 

Ambient temperature is displayed  

Room temperature is displayed  

4-digit  7-segment display for various values  

Display of operating hours  

Warning: an error is recorded 

Recirculating air operation is activated  

Automatic blower control is activated  

Bar display for blower speed in manual blower control mode 

Manual blower control is activated  

10 

Demisting operation is activated 

11 

Cooling operation is activated  

12 

ECON operation is activated  

 

 

Содержание KL30

Страница 1: ...t Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA Air Conditioning unit KL30 KL30T with control KS50 Versions 12 respectively 24 Volt DC Fresh Air Heating ID BBA KL30T12AD Version A02 ...

Страница 2: ...ning unit 8 5 3 Switch off air conditioning unit 8 5 4 Setting of the desired temperature 8 5 5 Manual adjustment of the blowers 9 5 6 ECON operation 9 5 7 Fresh and recirculating air operation 10 5 8 Demisting operation 10 5 9 Changeover temperature display mode 11 5 10 Switch the temperature indication to Fahrenheit 12 6 Maintenance Service 12 6 1 Compressor 12 6 2 Return air grid 12 6 3 Condens...

Страница 3: ...increases operation reliability and service life of the air condi tioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any...

Страница 4: ...se your product is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without notice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the ab...

Страница 5: ...aft seal of the compressor The compressor should be started every 4 weeks for approx 15 minutes This also applies when the vehicle is not into operation for a longer period or when the air condition ing unit is not used Compressor Type SD7H15 Weight kg approx 7 5 Oil brand quantity liter PAG depend ing on version3 Magnetic clutch 2 24V DC Attention for SD7H15 Only clockwise rotation 1 Weight witho...

Страница 6: ...NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be operated under aggressive envi ronmental conditions i e air containing salt phosphate or ammoniac extremely a corrosion of the cupper and aluminium components can not be ruled out The cupper and aluminium components of the KONVEKTA systems are not s...

Страница 7: ...Please note that the control panel keys have not been designed for heavy stressing Excessive or fast pressing of the keys for adjusting the set temperature does not accelerate the cooling down process It possibly damages the control panel and so affects the general perfor mance of the air conditioning unit 5 1 Description of the display LCD symbols Symbol Acceptation of the display symbols 1 Ambie...

Страница 8: ...ars here 20286 hours Now the A C is ready for operation The last stored setting is displayed 5 3 Switch off air conditioning unit By pressing the key Blowers Minus 2 longer than 2 seconds the A C is switched off While the key is pressed the display changes temporarily This is no fault no settings are changed Press and hold Now the A C is switched off 5 4 Setting of the desired temperature The set ...

Страница 9: ... 11 indicates that the unit is in cooling mode at the moment The ECON mode can be activated by pressing and holding key Set Tempera ture Minus 7 While the key is pressed the display changes temporarily This is no fault no settings are changed Press and hold Now the ECON mode is activated and the ECON symbol 12 is displayed In ECON mode the compressor is locked The A C operates only in ventilation ...

Страница 10: ...5 8 Demisting operation If the windows are steamed up the demisting mode can be activated Press key Demisting 4 to activate demisting operation mode Press The symbol Demisting 10 on the display indicates that the demisting mode is activated In demisting mode the compressor is operating and the blower speed is raised to 100 If the key Demisting 4 is pressed again the demisting mode gets deactivat e...

Страница 11: ...mbol Inside Temperature 2 appears By pressing key MODE 6 once again the display changes over to set tem perature indication Press The set temperature is displayed When the demisting mode is activated the blower speed is increased to 100 The speed can be adjusted manually on demand But to reach maximum demisting performance the blower speed should not be decreased If the set temperature is adjusted...

Страница 12: ...nd maintenance works please contact via email TKD konvekta com Danger of accidents Qualified staff in charge of installation and maintenance have to be trained in accordance with EN 378 Part 4 and EC No 307 2008 and must strictly follow the legal provisions Any works or modifications at the air conditioner which are carried out improperly can lead to mal function and so endanger operational reliab...

Страница 13: ...as switched off check evaporator blower replace if necessary outside temperature too low possible icing of evaporator switch on ventilation only 2 evaporator coil dirty clean evaporator coil with compressed air compressor does not compress check high and low pressure replace compressor if necessary excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil w...

Страница 14: ...lance Resolution for the waste management of old cars and the adaptation of road prescriptions Resolution EC No 2037 2000 of the Euro pean Parliament and of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulati...

Отзывы: