SmartClient-SLUx-170-P - User Guide, Rev. 1.0
// 28
5.2.
DC Power Connection
The SmartClient-SLUx-170-P is delivered with a power adapter with a 2-pin Phoenix power plug terminal attached as
well as a power cable. Users can (2-pin Phoenix connector) attached to a supplied power adapter. Users can use the
supplied power cord and power adapter to carry AC power from AC power source and then convert it into DC 12 V.
Users can also detach the Phoenix plug terminal from the power adapter and use it to prepare the connecting wires
for DC connection. DC power voltage should be 12 V.
Figure 11: Phoenix power plug terminal
1
Slotted pan head screw for securing the wire
2
Slotted pan head screw for securing the Phoenix plug terminal to the Phoenix connector
3
Location for inserting the positive (+) input wire
4 Location for inserting the negative (-) input wire
5.2.1.
Cabling
For the pin assignment Phoenix power plug terminal refer to the subsection 9.1.1 "Power Input Connector".
1.
Cut the required length two isolated wires ( 1mm2) AWG 18 and strip each end 5 ~ 7 mm.
2.
Twist the striped wire-ends and provide them with ferrules.
3.
Loosen the two slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the
prepared wires.
4.
Insert the wires into the corresponding clamp of the Phoenix plug terminal. Make sure that you have the right
polarity of the connection [refer to Figure 11 or subsection 9.1.1 "Power Input Connector"].
5.
Fasten the screws to secure the wires into the clamps of the plug terminal.
1
1
2
2
3
4