Parallel Port Interface
The MOPSlcdLX incorporates a parallel port that can be set to uni-/bidirectional and supports EPP operating
modes.
10.1
Connector
The parallel port is available through the X15004 connector (26 pins). To have the signals available on a
standard parallel interface connector DSUB25 an adapter cable is required which is offered by KONTRON
(KAB-DSUB25-1, part number 96015-0000-00-0).
Header
Pin
Signal Name
Function
DSUB25
1
/STB
Strobe
1
2
/AFD
Autofeed
14
3
D0
Data 0
2
4
/ERR
Error
15
5
D1
Data 1
3
6
/INIT
Init
16
7
D2
Data 2
4
8
/SLIN
Select in
17
9
D3
Data 3
5
10
GND
Ground
18
11
D4
Data 4
6
12
GND
Ground
19
13
D5
Data 5
7
14
GND
Ground
20
15
D6
Data 6
8
16
GND
Ground
21
17
D7
Data 7
9
18
GND
Ground
22
19
/ACK
Acknowledge
10
20
GND
Ground
23
21
/BUSY
Busy
11
22
GND
Ground
24
23
PE
Paper out
12
24
GND
Ground
25
25
/SLCT
Select out
13
26
VCC
1)
Power +5V
---
Note:
1)
To protect the external power lines of peripheral device make sure that
- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.