FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99
// 33
Table 16: Environmental Specification FlatClient ECO and FlatClient PRO Line
Operating Altitude
Up to 3000 m (9900 ft)
Storage Altitude
Up to 5000 m (16500 ft)
Humidity
10%-90% @ 39°C, non condensing
Certification
CE, cULus (only for Haswell and BayTrail CPU)
Protection Class
Front: IP65, Housing IP20
Shock, according to EN
60068-2-27
15 G 11 ms duration (half sine)
Vibration, according to
EN 60068-2-6
10-500 Hz: 1G/3 axis
Table 17: CE Directives and standards CE Directives
Low Voltage Directive (Electrical Safety)
2014/35/EU
EMC Directive
2014/30/EU
RoHS II Directives
E2011/65/EU + 2015/863/EU + 2017/2102/EU
Safety
EN62368-1:2014 + AC:2015 Audio/video, information and communication
technology equipment – Part 1: Safety requirements (IEC 62368-1:2014,
mo Cor.:2015)
EMC
Immunity: EN61000-6-2:2005 + Cor.:2005 Electromagnetic compatibility
(EMC), Part 6-2: Generic Standards - Immunity for industrial
envir CENELEC- Cor.:2005
Emission: EN55032:2015 Information technology equipment, Radio
disturbance characteristics, Limits and methods of measurement (CISPR
32:2015)
FlatClient MAR is intended for indoor use only. To avoid product damage do not use in a
sheltered outdoor, outdoor or sunlit environment.
Observe that the product is not exposed to direct sunlight (UV radiation):
•
Prolonged exposure shortens field life and voids the warranty
•
Short exposure may lead to higher temperatures inside the product and cause
permanent damage
•
Direct exposure accelerates long-term aging
For intend use in an outdoor environment or a sunlit environment, contact your Kontron
representative.