D R A F T — F O R I N
T E R N A L U S E O N L Y
13
www.kontron.com
User Guide
CP6105X
1.4 Standards
This product complies with the requirements of the following standards.
Note:
Customers desiring to perform further environmental testing of the CP6105X must contact
Kontron for assistance prior to performing any such testing.
Boards
without conformal coating
must not be exposed to a change of temperature which
can lead to condensation, as this may cause irreversible damage especially when the board
is powered up again.
Kontron does not accept any responsibility for damage to products resulting from destruc-
tive environmental testing.
Table 2: Standards
TYPE
ASPECT
STANDARD
REMARKS
CE
Emission
EN 55022 Class B, IEC 61000-6-3
--
Immunity
EN 55024, IEC 61000-6-2
--
Electrical Safety
EN 60950-1
--
Mechanical
Mechanical Dimensions IEEE 1101.10
--
Environmental
Climatic Humidity
IEC 60068-2-78 (see note below)
--
WEEE
Directive 2002/96/EC
Waste electrical and electronic
equipment
--
RoHS 2
Directive 2011/65/EU
Restriction of the use of certain
hazardous substances in electrical
and electronic equipment
--
Operating Vibration
(Sinusoidal)
IEC 60068-2-6
Ruggedized version test parameters:
10-300 (Hz) frequency range
5 (g) acceleration
1 (oct/min) sweep rate
10 cycles/axis
3 axes
Operating Shocks
IEC 60068-2-27
Ruggedized version test parameters:
30 (g) acceleration
9 (ms) shock duration half sine
3 number of shocks per direction
(total: 18)
6 directions
5 (s) recovery time
Operating Bumps
IEC 60068-2-27
Ruggedized version test parameters:
15 (g) acceleration
11 (ms) shock duration half sine
500 number of shocks per direction
6 directions
1 (s) recovery time