AM4011
Installation
ID 1022-1626, Rev. 1.0
Page 3 - 7
P R E L I M I N A R Y
3.3.2
Hot Swap Extraction
To extract the AMC module proceed as follows:
1. Ensure that the safety requirements indicated in section 3.1 are observed. Particular at-
tention must be paid to the warning regarding the heat sink!
2. Pull the module handle in the “Hot Swap” position.
When the module handle is in the “Hot Swap” position, the extraction process of the mod-
ule is initiated and the following occurs:
•
The BLUE HS LED displays short blinks.
When the carrier/chassis IPMI controller receives the handle opened event, it sends
a command to the MMC with a request to perform short blinks of the BLUE HS LED.
This indicates that the module is waiting to be deactivated.
Now the module waits for a permission from the higher level management (Shelf Man-
ager or System Manager) to proceed with its deactivation.
Once the module receives the permission to continue the deactivation, all used ports
are disabled.
•
The BLUE HS LED turns on.
The Intelligent Platform Management Controller on the carrier/chassis disables the
module's payload power and the BLUE HS LED is turned on.
Now the module is ready to be safely extracted.
3. Pull the module handle in the “Unlocked” position.
3. Disconnect any interfacing cables that may be connected to the module.
4. Disengage the module from the carrier/backplane connector by pulling on the module
handle. This may require a considerable amount of force.
5. Using the front panel as a grip, remove the module from the carrier/chassis.
6. Dispose of the module as required.
Warning!
Due care should be exercised when handling the module due to the fact
that the heat sink can get very hot. Do not touch the heat sink when remov-
ing the module.
Содержание AM4011
Страница 10: ...Preface AM4011 This page has been intentionally left blank Page x ID 1022 1626 Rev 1 0 P R E L I M I N A R Y...
Страница 16: ...Preface AM4011 This page has been intentionally left blank Page xvi ID 1022 1626 Rev 1 0 P R E L I M I N A R Y...
Страница 17: ...AM4011 Introduction ID 1022 1626 Rev 1 0 Page 1 1 Introduction Chapter 1 1 P R E L I M I N A R Y...
Страница 59: ...AM4011 Installation ID 1022 1626 Rev 1 0 Page 3 1 Installation Chapter 1 3 P R E L I M I N A R Y...
Страница 69: ...AM4011 Configuration ID 1022 1626 Rev 1 0 Page 4 1 Configuration Chapter 1 4 P R E L I M I N A R Y...