Board Features
8
X
Exceed critical threshold
*
Power On/Off
-
Power On
N
No change
2.4.2.1
IPMB-L Link Sensor
The AM4330 has an IPMB-L links to communicate with the AMC Carrier and other chassis devices on
the chassis IPMB-0 bus. MMC monitors the bus for any link failure and send the bus failure event to
the AMC Carrier upon the recovery occurs.
2.4.2.2
Module Hot Swap
The hot-swap event message conveys the current state of the module, the previous state, and a
cause of the state change as can be determined by the MMC. Refer to AMC.0 R2.0 Specifications for
further details on the module hot-swap state.
2.4.3
Field Replaceable Unit (FRU) Information
The FRU Information provides inventory data about the boards where the FRU Information Device is
located. The part number or version number can be read through software.
Board 3.3VSUS
3.3 V Suspend
*
X
Board 12.0V
12.0 V
-
X
VCC Bleu LED
5.0 V
*
X
Board 2.5V
2.5 V
-
X
Board V1.5V
1.5 V
-
X
Board 1.0V
1.0 V
-
X
Temp AirInlet
Board Inlet Temperature
-
X
Temp 8155
Temperature 8155
*
X
Temp PEX
Temperature 8114
*
X
Temp Exhaust
Board Outlet Temperature
*
X
PexLaneGood 0
PCIE lane 0 detection
-
N
PexLaneGood 1
PCIE lane 1 detection
-
N
PexLaneGood 2
PCIE lane 2 detection
-
N
PexLaneGood 3
PCIE lane 3 detection
-
N
Health Error
Board health sensors (aggregation of other sensors)
*
Asserted /
Desserted
IPMC Reboot
IPMC reboot detection
*
N
Ver change
IPMC firmware upgrade detection
*
N
Sensor Name
Voltage/Signals Monitored
Scanning Enabled
under Power
State
Health LED
(Green to Red)