Kontron 11524 Скачать руководство пользователя страница 34

Control Unit CUmini 5x-2x0x - Rev. 1.A 

 

www.kontron.com 

 

// 34 

 

10.2.

 

Returning Defective Merchandise

 

All equipment returned to Kontron must have a Return of Material Authorization (RMA) number assigned exclusively 
by Kontron. Kontron cannot be held responsible for any loss or damage caused to the equipment received without an 
RMA number. The buyer accepts responsibility for all freight charges for the return of goods to Kontron's designated 
facility. Kontron will pay the return freight charges back to the buyer's location in the event that the equipment is 
repaired or replaced within the stipulated warranty period. Follow these steps before returning any product to 
Kontron. 

1.

 

Visit the RMA Information website: 

http://www.kontron.com/support-and-services/support/rma-information 

 

Download the RMA Request sheet for 

Kontron Europe GmbH

 and fill out the form. Take care to include a short 

detailed description of the observed problem or failure and to include the product identification Information 

es more than one 

product, fill out the above information in the RMA Request form for each product. 
 

2.

 

Send the completed RMA-Request form to the fax or email address given below at Kontron Europe GmbH. 
Kontron will provide an RMA-Number. 

 

Kontron Europe GmbH 
RMA Support 
Phone: 

+49 (0) 821 4086-0 

Fax:  

+49 (0) 821 4086 111 

Email: 

 [email protected] 

 

 

3.

 

The goods for repair must be packed properly for shipping, considering shock and ESD protection. 

 

 

 

Goods returned to Kontron Europe GmbH in non-proper packaging will be considered as 
customer caused faults and cannot be accepted as warranty repairs. 

 

4.

 

Include the RMA-Number with the shipping paperwork and send the product to the delivery address provided in 
the RMA form or received from Kontron RMA Support. 

 

 

  

Содержание 11524

Страница 1: ...USER GUIDE www kontron com Control Unit CUmini 5x 2x0x Doc Rev 1 A Doc ID 90212 EN...

Страница 2: ...Control Unit CUmini 5x 2x0x Rev 1 A www kontron com 2 This page has been intentionally left blank...

Страница 3: ...lication will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and ins...

Страница 4: ...rely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for compliance with all le...

Страница 5: ...fer to the corporate offices contact information on the last page of this user guide or visit our website CONTACT US Customer Support Find Kontron contacts by visiting http www kontron com support Cus...

Страница 6: ...rescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensit...

Страница 7: ...operations on this product Therefore always unplug the power cable and any other cables which provide external voltages before performing any work on this product Earth ground connection to a central...

Страница 8: ...product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmenta...

Страница 9: ...r supply 14 2 4 Materials 15 2 5 Type Label and Product Indentification 15 2 6 Accessories 16 3 Design and function 17 3 1 Description of function 17 3 1 1 Processor 17 3 1 2 BIOS 17 3 1 3 NOR Flash 1...

Страница 10: ...List of Acronyms 35 Appendix B Product Configurations 36 About Kontron 40 List of Tables Table 1 Product Versions 11 Table 2 Detail configuration of the product versions 11 Table 3 Zubeh r for the Co...

Страница 11: ...quantities apply For details please contact our sales team Table 1 Product Versions Article No Name Versions 11529 Control Unit CUmini 54 2500 48021 Compact Control Unit with Intel Atom E3845 11592 Co...

Страница 12: ...rise license Linux Debian Software Soft PLC CODESYS Runtime system license Soft PLC CODESYS Target Visu license Soft PLC CODESYS Web Visu license Mechanik Stainless steel housing with DIN rail clamp x...

Страница 13: ...endent Watchdog Timer Power Button 1x programmable status LED Power supply 24 VDC 20 on 3 pin Phoenix connector DIN rail mounting vertical book form 2 1 Dimensions and weight External dimensions W H D...

Страница 14: ...30 W The output of the power supply unit must meet the criteria of a safety extra low voltage SELV according to IEC 60664 1 The use of an unsuitable power supply unit can result in danger of electric...

Страница 15: ...ron de ueber uns corporate responsibility material declaration reach customer information 2 5 Type Label and Product Indentification The type plate is located on the bottom opposite the heat sink of t...

Страница 16: ...Zubeh r for the Control Unit Article No Designation Comment 90211 Handbuch Control Unit CUmini 5x 2x0x Deutsches Handbuch 90196 System Manual Linux Deutsches Handbuch 90212 User Guide Control Unit CU...

Страница 17: ...it Operating systems UEFI Legacy Boot Option Booting from USB LAN SD and eMMC Virtualization Intel VT x Built in UEFI Shell BIOS Password Execute Disable XD USB Support Fast Boot 3 1 3 NOR Flash The N...

Страница 18: ...AM up to 512kByte The SRAM is supplied by the backup battery in case of power failure FRAM do not require a power supply for data storage Under Windows operating system SRAM or FRAM is not supported 3...

Страница 19: ...temperature is used to throttle the clock rate and to shut down the operating system in case of overtemperature 3 1 10 RTC The RTC RX 8564LC from Seiko Epson is used as clock component In combination...

Страница 20: ...gable terminal pitch 5 mm for 24 VDC supply Power X2 RJ45 8P8C Connector for Ethernet Ethernet X3 RJ45 8P8C Connector for Ethernet Ethernet X4 2 port USB Host connector type A USB 2 0 X6 microSD Card...

Страница 21: ...24V Power supply 24 VDC 20 Cable acc to chapter 2 2 EMC max 3 m unshielded Connector type Phoenix MSTBA 2 5 3 G 1757488 Mating connector Phoenix FKCN 2 5 3 ST 5 08 1873061 included in delivery Associa...

Страница 22: ...ich is double shielded with a cable length of less than 3m Otherwise compliance with the applicable EMC standards cannot be guaranteed Kontron recommends the use of a certified Premium High Speed HDMI...

Страница 23: ...be properly grounded Compliance with the prescribed EMC limit values can only be guaranteed if the device is properly grounded Damage to plugs or cables due to improper handling when plugging in and p...

Страница 24: ...gure 4 A minimum distance of 10 cm must be maintained to other devices or objects on the DIN rail on both sides If necessary the distance must be increased if the installation regulations of the neigh...

Страница 25: ...alled automatically at the same time In this way Microsoft guarantees the secure use of its operating system for industrial customers without them being confronted with compatibility problems as in th...

Страница 26: ...ckage contains all device descriptions and libraries for the CODESYS development environment The CODESYS Device Package can be ordered free of charge from Kontron Electronics AG at support kontron ch...

Страница 27: ...device via USB stick or SD card With a backup of the system the devices can be reset to a defined state or even cloned The backup restore function is integrated in the system configuration and can be...

Страница 28: ...correct orientation as shown in the illustrations below Figure 5 Battery replacement Pull out the tab of the battery holder and thus the whole battery holder out of the device Remove the old battery...

Страница 29: ...EU Battery Directive and Regulation EC No 1907 2006 REACH Recommended by Kontron Electronics AG are Renata Varta and Panasonic Batteries must not be disposed of with household waste and must not be i...

Страница 30: ...age over HDMI Settings in BIOS are not correct Contact the support Interface function impaired Interface cable not plugged in correctly Check whether all interface cables are plugged in correctly and...

Страница 31: ...he household waste and do not burn them Remove the backup battery from the device and dispose of it separately Kontron will gladly take back old electrical equipment at the end of its service life for...

Страница 32: ...Control Unit CUmini 5x 2x0x Rev 1 A www kontron com 32 9 Technical drawings 9 1 Views and dimensions Figure 6 Views and dimensions...

Страница 33: ...icle number or product ID number PN Production batch or Serial Number SN The numbers are located on a small label on the nameplate Be ready to explain the nature of your problem to the service technic...

Страница 34: ...ation Download the RMA Request sheet for Kontron Europe GmbH and fill out the form Take care to include a short detailed description of the observed problem or failure and to include the product ident...

Страница 35: ...s ESD Electrostatic Discharge electrostatic discharge high electrical voltage pulse HDMI High Definition Multimedia Interface Interface for digital image sound transmission in consumer electronics sub...

Страница 36: ...method X DIN rail upright book form 5 6 FRAM X 64kB 4 128kB 5 256kB 6 512kB 7 7 Ethernet X 0 Ports 0 1 Port 1 2 Ports 2 3 Temperature Range X Standard 0 C 55 C 0 4 RAM X 2GB 4 4GB 5 5 Flash X 16GB eMM...

Страница 37: ...Control Unit CUmini 5x 2x0x Rev 1 A www kontron com 37 This page has been intentionally left blank...

Страница 38: ...Control Unit CUmini 5x 2x0x Rev 1 A www kontron com 38 This page has been intentionally left blank...

Страница 39: ...Control Unit CUmini 5x 2x0x Rev 1 A www kontron com 39 This page has been intentionally left blank...

Страница 40: ...the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benefit from accelerated time to market reduced total cost of owner...

Отзывы: