Safety Notices 

Compliance is required with respect to voltage, frequency, and current 
requirements indicated on the manufacturer’s label. Connection to a 
di

erent power source than those speci

fi

ed may result in improper 

operation, damage to the equipment or pose a 

fi

re hazard if the 

limitations are not followed. 

2. There are no operator serviceable parts inside this equipment. Service 
should be provided only by a quali

fi

ed service technician. 

3. This equipment is provided with a detachable power cord which has 
an integral safety ground wire intended for connection to a grounded 
safety outlet. 

a. Do not substitute the power cord with one that is not the provided 
approved type. Never use an adapter plug to connect to a 2-wire 
outlet as this will defeat the continuity of the grounding wire. 

b. The equipment requires the use of the ground wire as a part of the 
safety certi

fi

cation, modi

fi

cation or misuse can provide a shock 

hazard that can result in serious injury or death. 

c. Contact a quali

fi

ed electrician or the manufacturer if there 

are questions about the installation prior to connecting the 
equipment. 

d. Protective earthing is provided by Listed AC adapter. Building 
installation shall provide appropriate short-circuit backup 
protection. 

e. Protective bonding must be installed in accordance with local 
national wiring rules and regulations. 

5

System Requirements 

• Mac OS X or Microsoft Windows 7/8/10 

• Web Browser: Safari, Google Chrome, Microsoft Internet Explorer 

10 or Mozilla Firefox. 

• BlackMagic Atem Software Control 6.9 (or above) 

System Topology 

• Connect the one end of the supplied 1m CAT5 cable to your ATEM 

switcher and the other end to the LAN port of the POE injector. 

• Connect the RED RJ45 Connector of the supplied 2m CAT5 to the 

POE port on the POE injector and the NEUTRIK connector end to 

your kontrol device.  

• Power up your ATEM. 

• Power up your kontrol. 

• Your kontrol unit should now boot up with a test sequence. 

2

Web Con

fi

guration 

Your control devices comes with a basic web con

fi

guration tool to assist 

with your setup. To enter the web con

fi

guration tool, power your control 

device. During the pre-startup sequence your  controller will display 

fi

rmware version as well as your product serial number on the 

SmartSwitch. For products without a display or SmartSwitches, this 

information can also be found in the web con

fi

g.  

After the pre-boot sequence you will notice the CUT button change 

from AMBER to RED. Press and hold the RED cut button until all Buttons 

turn red. You are now in con

fi

t mode and your controller will default to 

IP 192.168.10.99. This feature is to assist in cases where you cannot 

remember the IP you have set before. 

Now that you are in con

fi

g mode you can  connect your computer to 

your controller. Keep in mind that your Control device does not have a 

DHCP server and that you will have to set your computer IP manually. 

After you have con

fi

gured your computers IP settings, you can now 

open your favorite web browser and type 192.168.10.99 into the 

address bar. you will then be directed to your Kontrol web con

fi

guration 

tool from where you can change some basic settings. 

After you have made your required changes. click submit and power 

cycle your device  for changes to take e

ect 