Note: The tee adapter is not needed when using a mask.

4) Check that the POWER switch is in the “off” position. Plug the power cord

into a main outlet.

5) Press the POWER switch to the “ ON” position.

6) Start your treatment according to your physician’s or therapist’s

instructions.

7) Once the treatment is complete, press the POWER switch to the “off”

position and unplug the power cord from the outlet.

IMPORTANT!

The Compressor will automatically shut off if it becomes overheated. If/When

this happens, immediately:

1) Press the POWER switch to the “ off” position.

2) Unplug the power cord from the outlet.

3) Allow the motor to cool for 30 minutes.

Before restarting the unit, make sure that the air vents are not obstructed.

After Every Use

1) Unplug the unit from the power source.

2) Allow the unit to completely cool.

3) Carefully detach the air tubing from the Nebulizer and pour out any

remaining medication.

4) Follow the cleaning procedures provided in this manual.

Trouble Shooting

If any abnormality occurs during use, please check and correct the following:

Condition

Correction

Remarks

Unit does not

operate when

POWER

switch is

pressed.

Check the AC connection to the outlet

Содержание 408D

Страница 1: ...completely before operating this unit Congratulations on having purchased Medical Air Compressor Nebulizer We warrant that this device has been produced using high quantity materials and it complies...

Страница 2: ...2 Drawing Symbols Abbreviation Warning Fragile Wet Upper II Type Equipment B Type Applied Part Power Off Power On...

Страница 3: ...on standard AC power Treatments are delivered quickly safely and conveniently making this unit ideal for all ages We encourage you to thoroughly read this manual to learn about the features of your N...

Страница 4: ...ely unplug the unit Do not use the unit if it has any damaged parts including power cord or plug if it has been submersed in water or dropped Promptly send unit for examination and repair The unit sho...

Страница 5: ...the POWER switch has been turned to the off position and the unit has been disconnected from the power source 2 Disconnect the air tube from the base of the Nebulizer 3 Gently twist and pull up on th...

Страница 6: ...n a flat stable surface within reach with the handle facing toward you 2 Open the storage compartment by lifting the lid Remove the contents Nebulizer mouthpiece and air tube 3 Gently twist and pull s...

Страница 7: ...this happens immediately 1 Press the POWER switch to the off position 2 Unplug the power cord from the outlet 3 Allow the motor to cool for 30 minutes Before restarting the unit make sure that the air...

Страница 8: ...er AC 220V 22V 50Hz 1Hz AC 110V 11V 60Hz 1Hz Current 0 8A Power Consumption 80W Medicine Capacity 5mL Sound Level 58 dB A Compressor Pressure Range 210kPa to 250 kPa Operating Pressure Range 50 kPa 10...

Страница 9: ...rds and carefully inspected prior to shipment This warranty is an expression of our confidence in the materials and workmanship of our products and our assurance to the consumer of years of dependable...

Страница 10: ...And Technology Co Ltd Address NO 8 Shengchang West Road Danyang Development Zone Jiangsu Province 212300 P R China Tel 86 511 86375968 WhatsApp 0086 18952012596 mail info konsung com Website www kons...

Отзывы: