Könner & Söhnen KS B1A Скачать руководство пользователя страница 4

www.ks-power.de/en   

|

    3

4

SPECIFICATIONS

5

TROUBLESHOOTING

RATED OUTPUT VOLTAGE

6V/DC

direct current

12V/DC

direct current

Maximum input power

8W

16W

Rated output voltage

7.2V DC ± 0.2V

7.2V DC ± 0.2V

Rated output current

1A

Rated input voltage

10

0V AC-240V AC / 50HZ / 60Hz

Operating temperature

(-10

0

) - (+40

0

)

Storage temperature

(-30

0

) - (+60

0

)

Dimensions, cm

12.50 х 6.90 х 7.20

Weight, kg

0.20

No.

FAULT

REMEDY

1.

Charger does not 

respond when turned 

on

1). Check the mains outlet 

2). Return the charger to a service center for 

inspection

2.

Power indicator is 

on, but the charging 

process does not start

1). Check connection of the terminals to the 

battery 

2). Check the terminals for sulfiding

 

3). Check the terminal wire for damage. If it 

is damaged, do not try to replace it yourself. 

Return the charger to the service center. 

4). The charger has activated overtemperature 

protection. Wait a while for the charger to cool 

down. 

5). Wrong battery voltage has been selected

3.

Power indicator is off 

when the charger is 

working

Indicator is faulty

4.

6V or 12V indicator 

does not light up when 

the charger is working

Indicator is faulty

5.

6V/12V cannot be 

switched

Return the charger to the service center for 

testing Indicator is faulty

Содержание KS B1A

Страница 1: ...Automatic Battery Charger Please read this manual carefully before use Owner s Manual KS B1A EN ...

Страница 2: ...er de en This automatic battery charger is intended for charging 6 V 12 V lead acid batteries It is used to charge batteries of generators cultivators motorcycles snowmobiles boats four wheelers etc with a capacity of up to 32 A h After selecting the required voltage the charging process is carried out automatically 1 Getting started Connect the red terminal to the side of the battery and the blac...

Страница 3: ... indicator 2 Fault indicator 3 Mode selection button 3 Mode selection button 4 6 V indicator 4 6 V indicator 5 5 12 V 12 V indicator indicator 1 1 5 5 2 2 3 3 4 4 2 Press the MODE button to select the appropriate charging voltage that matches the battery s rated voltage select 6 V charging voltage for a 6 V battery and 12 V charging voltage for a 12 V battery The selected mode will turn green 3 Th...

Страница 4: ... for inspection 2 Power indicator is on but the charging process does not start 1 Check connection of the terminals to the battery 2 Check the terminals for sulfiding 3 Check the terminal wire for damage If it is damaged do not try to replace it yourself Return the charger to the service center 4 The charger has activated overtemperature protection Wait a while for the charger to cool down 5 Wrong...

Страница 5: ...turer warranty is 1 year The warranty period starts from the date of purchase In cases where a warranty period is longer than 1 year according to local legislation please contact your local dealer The Seller of the product is responsible for granting the warranty Please contact the Seller for warranty If the product fails within the warranty period because of defects in workmanship it will be exch...

Страница 6: ...und Unterstützung und Unterstützung support dimaxgroup de Garantie Reparatur und Service Garantie Reparatur und Service service dimaxgroup de Sonstiges Sonstiges info dimaxgroup de Polska Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de Україна Україна ТОВ Техно Трейд КС вул Електротехнічна 47 02222 м Київ Україна www ks pow...

Отзывы: