KonNad C2000-A2-SMD4440-AE1 Скачать руководство пользователя страница 8

1.3. Indicators

Classification

Indicator

Description

Meaning

Digital Input

DIx

Digital input

indicators (dry

contact)

Steady on:Short to GND

Off:Open

Digital

Output

DOx

Digital input

indicators

Steady on:On

Off:Off

Downstream

Serial Port

RXD

RS485 data receive

indicator

Steady on:RS485 line fault, please check if the positive

and negative poles of 485 line are reversed

Flashing:RS485 receiving data

Off:RS485 no receiving data

TXD

RS485 data

transmit indicator

Flashing:RS485 transmitting data

Off:RS485 no transmitting data

Power

PWR

Power indicator

Steady on:Normal power supply

Off:No power or abnormal power supply, please

check if the voltage range is 9~27VDC

RUN

RUN

Running indicator

Steady on:Device exception

Flashing:Flashes every 1 second when the device is

ready

Off:Device exception

C2000-A2-SMD4440-AE1 User Manual

8 / 12

SinoCon Co., Ltd. 

www.sinoconsys.com

Содержание C2000-A2-SMD4440-AE1

Страница 1: ...Last updated 2019 12 13 C2000 A2 SMD4440 AE1 User Manual RS485 4DI 4AI 4DO 0 20 4 20 mA Remote I O Module RS485 Analog I O Module SinoCon Co Ltd...

Страница 2: ...dware Description 1 1 Specifications 1 2 Apprearance 1 3 Indicators 1 4 Port Description 1 5 Product Dimensions 1 6 Installation Method 2 Package Contents 3 Warranty Policy C2000 A2 SMD4440 AE1 User M...

Страница 3: ...liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific...

Страница 4: ...C2000 A2 SMD4440 AE1 User Manual 4 12 SinoCon Co Ltd www sinoconsys com...

Страница 5: ...nalog Input AI Channels 4 Connector Terminal block Acquisition Range 0 20 4 20mA Acquisition Accuracy 3 Resolution 12 bit Acquisition Characteristics Single input Acquisition Frequency 250Hz Input Imp...

Страница 6: ...Current 80mA 12VDC Physical Characteristics Dimensions 75 105 30mm Installation Din rail or wall Environmental Limits Operating Temperature 40 85 Storage Temperature 60 125 Ambient Relative Humidity 5...

Страница 7: ...1 2 Apprearance C2000 A2 SMD4440 AE1 User Manual 7 12 SinoCon Co Ltd www sinoconsys com...

Страница 8: ...ive poles of 485 line are reversed Flashing RS485 receiving data Off RS485 no receiving data TXD RS485 data transmit indicator Flashing RS485 transmitting data Off RS485 no transmitting data Power PWR...

Страница 9: ...input Negative analog input RVV 2 0 5 Digital Output NO Digital output normally open RVV 2 1 0 COM Digital output common RVV 2 1 0 NC Digital output normally close RVV 2 1 0 Upstream Serial Port RS48...

Страница 10: ...1 5 Product Dimensions unit mm inch 1 6 Installation Method C2000 A2 SMD4440 AE1 User Manual 10 12 SinoCon Co Ltd www sinoconsys com...

Страница 11: ...2 Package Contents No Contents 1 Device contain mounting kit 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 A2 SMD4440 AE1 User Manual 11 12 SinoCon Co Ltd www sinoconsys com...

Страница 12: ...period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty serv...

Отзывы: