Connection of electronic lock:
Lock without adapter, power supplied via outdoor unit. When the
door is closed, the circuit voltage is 0 V. By unlocking the door the
circuit voltage 12 V. Delay is 4~7 seconds.
Lock without adapter, power supplied via outdoor unit. When the
door is closed, the circuit voltage is 12 V. By unlocking the door the
circuit voltage 0 V. Delay is 4~7 seconds.
Description and operation of the outdoor unit:
1. Loudspeaker
2. Camera
3. IR LED for night view
4. Call button
5. Microphone
• Press the call button
• The indoor monitor will give a ding
dong sound and activate the monitor
screen
Description of the indoor monitor: