53
Click codes
When the control unit is switched on its relays to inform the user
acoustically about the system state and the reason why the control
unit was switched off before. The table below shows which number
of clicks corresponds to certain information.
Number of clicks
State information
1x
Key lock active:
This signal will be put out every time if the
desktop shall be moved and the key lock is
active. (Up/Down
-
Key or memory keys)
2x with short interval
(fast double click)
Normal operation:
No problems detected. This signal will be put
out only when the control unit is connected to
mains power.
2x with long interval
(slow double click)
Reset mode:
The system was put into reset mode. This
signal will be put out every time if the desk
-
top shall be moved in reset mode.
(Up/Down
-
Key or memory keys)
3x with short interval
(fast triple click)
Sensor missing:
The safety sensor is not connected to the
control unit. This signal will be put our every
time if the desktop shall be moved.
(Up/Down
-
Key or memory keys)
3x with long interval
(slow triple click)
Duty cycle exceeded:
This signal will be put out every time it the
desktop shall be moved downwards.
(Down
-
Key)
You must follow the safety instructions! Improper use of
the system poses a risk of material damage and personal
injury!