2
ENGLISH
INDICATION
STATUS
1. NORMAL (GREEN LED)
Lights up when supply is in normal condition and
flashes when UPS is regulating
2. BACKUP (YELLOW LED)
Lights up when battery is in backup mode and
flashes when battery has a low voltage
3. FAULT (RED LED)
Flashes when malfunction or overload occurs
4. OUTPUT SOCKET (Surge
protection only)
Connect with load equipment. Surge protection
only.
5. OUTPUT SOCKET (Surge
prot UPS)
Connect with load equipment. Surge prot
UPS
6. POWER SWITCH
Press the “Power” button for 4 seconds to turn
on/off the UPS.
7. RESET CIRCUIT BREAKER Reset circuit breaker protection
8. INPUT POWER CORD
Connect to AC Power
9. OUTPUT PHONE JACK
Connect to the Tel/Fax/Modem by another phone
line.
10. INPUT PHONE JACK
Insert the phone line into the jack.
Voltage DJ
The Voltage DJ guard the incoming voltage. When the voltage exceeds a limit, the
UPS will be activated. With the dipswitches 1 and 2 the lower limit can be set and the
higher limit can be set with dipswitch 3.
Lowest limit
Highest limit
160V (default)
180V
196V
265V (default)
275V
1: OFF
1: ON
1: OFF
3: OFF
3: ON
2: OFF
2: OFF
2: ON