background image

KÖNIG & MEYER

GmbH & Co. KG 

Kiesweg 2, 97877 Wertheim, www.k-m.de

18876-000-55  Rev.1  03-80-887-00  11/14

TECHNICAL DATA

Material

Tray: Aluminum, powder coating black
Edge protectors: exterior plastic, black
interior metal clamp fitting
Rubber knobs: Plastic, PU black

Dimensions

Support: W x D x H  640 x 63 x 325 mm

Packaging

Box: 745  x 115  x 335 mm

Weight

0.96 kg

SETUP INSTRUCTIONS

MAINTENANCE, CLEANING

18876  Master Keyboard 
Tray 

- perfect fit for the 18860 »Spider Pro« support arms
- stable aluminum tray 
- equipped with a keyboard stop
- side keyboard stops ensure that the tray is secure
- with integrated carrying handle and cable guide
- with edge protectors

SAFETY NOTES

Thank you for choosing this product. The instructions 
provide directions to all of the important set up and handling steps. 
We recommend you keep these instructions for future reference.

Assembly of the TRAY is very simple.

1

.a

Setup »Spider Pro« 18860:

1.a

Place the support arms at the desired height and... 

1.b

...secure it with the clamp screw.

2

.a

Insert the arms as far as they will go and...

2.a

...secure this position by placing the pins into the drill 

2.a

holes located closest to the stand tube.

3

.a

Place the tray onto the support arms.

3.a

ENSURE: that side brackets face downwards and...

3.a

...cover both support arms.  

4

Adhere the rubber knobs (4 knobs) to the proper positions  

4

on the tray to create a non-slip surface, if needed.

USAGE NOTES

Adjusting the Height

The tray is suitable for all 
support arm adjustment heights.

Should the height of the support arms
need to be adjusted, then remove the 
the tray from the support arms,
make the height adjustments,
once the adjustment have been made 
place the tray onto the support arms.

- Not suited for »Spider« models 18840 and 18850
- The tray is not affixed to the support arms, rather it is placed 

-

on top of the support arms. "Bumping" into the tray from below 

-

should be avoided, this can result in the tray slipping and 

-

damage to the equipment on the tray. 

- Please ensure that the tray is placed on the support arms 

-

properly and centered.

- In the event the product is damaged discontinue use.

- to care for the product use a damp cloth 

-

and a non-abrasive cleaning agent

FAULT-FINDING (F) and REPAIR (R)
F: Tray is not stable   

F:

R: Check to ensure that it is level i.e. balanced

F:

R: The support arms must be parallel to each other. 

F: R:

After placing equipment onto the tray, the weight of 

F: R:

the tray will also correct any minor imbalances.

F: Keyboard is not stable 

F:

R: Check the position of the rubber knobs.

Отзывы: