background image

INFORMATION FOR THE USER

A  HOW TO USE WITH AN EXTERNAL CABLE

A.a. ATTACH CABLE 

A.a. 

- attach cable when fishpole is extended 

A.a. 

- wrap the cable along the extended fishpole and secure by suitable means (e.g. adhesive band, etc.) 

 

A.b. TELESCOPICALLY EXTEND SECTIONS 

A.b. 

The locking collars need to be loosened 1-2 twists before extending the sections fully.  

A.b. 

Do not loosen all the locking collars at once. It is better to: 

A.b. 

- loosen the largest locking collar first, extend the first section, tighten the locking collar =(1) 

A.b. 

- loosen the next largest locking collar, extend the section, tighten the locking collar =(2), =(3), =(4),  

A.b. - 

until you have the rod length you require 

A.b. 

- wrap the cable along the rod and attach the microphone to the end thread (3/8”) or clamp 

 

A.c. RETRACT SECTIONS 

A.c. 

- unscrew/unclamp microphone, remove cable 

A.c. 

- loosen the smallest locking collar, fully retract the loose section, re-tighten the locking collar 

A.c. 

- loosen the next smallest locking collar, retract the section, and tighten the locking collar, etc. until  

A.c. - 

the fishpole is fully retracted. 

B  HOW TO USE WITH AN INTERNAL CABLE

- the microphone fishpole is delivered ready to use. 
- the materials used for the sections together with their conical construction give max. extension  

with min. total weight. However, the method for retracting and extending the rod is unlike that  

of more conventional microphone fishpoles. We recommend that you familiarize yourself with  

the functioning of the locking collars and how to extend and retract the rod. Do not attach the  

microphone until you feel comfortable with the functioning of the fishpole.   

- A cable can be run internally through the fishpole from the cable opening (not suitable for spiral  

cables)

B.a. INSERT CABLE 

B.a. 

- when the fishpole is retracted 

B.a. 

- unscrew the base cap (5) and insert the cable into the upper hole (at  

B.a. - 

the microphone) and push through until it reaches the largest section  

B.a. - 

and can carefully be pulled through while cautiously supplying more  

B.a. - 

cable to the upper opening. 

B.a. 

- push the cable through the base section cap and then replace the cap 

B.a. 

- if the cable is sufficiently flexible, lead it through the slit in the side of  

B.a. - 

the cap, which will stop the cable (max. ø 6 mm) being flattened or  

B.a. - 

kinked. Fit a strain stopper or use suitable adhesive tape. 

 

B.b. TELESCOPICALLY EXTEND SECTIONS see A.b. 

 

B.c. RETRACT SECTIONS 

 

B.c. 

- unscrew or unclamp the microphone 

B.c. 

- beginning with the smallest locking collar, loosen all the locking  

B.c. - 

collars, one after another and retract each section about 5-10cm,  

B.c. - 

leave the locking collars loose 

B.c. 

- hold the cable at the cable opening  and carefully push the base  

B.c. - 

section over the loosened sections until all the sections are  

B.c. - 

retracted. If necessary hold on to the sections. 

B.c. 

NOTE! 

B.c. 

The cable must not be squashed at the upper opening. 

B.c. 

- tighten the locking collars 

B.c. 

- roll up the cable and secure 

KÖNIG & MEYER

 GmbH & Co. KG 

Kiesweg 2, 97877 Wertheim, www.k-m.de 

23770-000-55  Rev.01  03-80-125-00  9/19

Отзывы: