![KONICS KRN1000 SERIES Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/konics/krn1000-series/krn1000-series_user-manual_1994598057.webp)
7
Menu
© Copyright Reserved KONICS Co., Ltd.
57
Low-limit
scale
value
High-limit
scale
value
Gradient
adjustment
value
Display
value
range
Same
result
=
Low-limit
scale
value
High-limit
scale
value
Gradient
adjustme
nt value
10.00
0.00
0.500
10.00
to 5.00
10.00
5.00
1.000
10.00
0.00
1.000
10.00
to 0.00
10.00
0.00
1.000
10.00
0.00
1.500
10.00
to -5.00
10.00
-5.00
1.000
※
3.
Number of digital inputs
In case of 4 input digital filters and 25ms sampling setting, it displays input sampling value
as moving average for 0.1 sec (100ms).
D1 = S1 , D2 =
S1 + S2
2
, D3 =
S1 + S2 + S3
3
Display values of D1, D2, D3 are the initial operation before averaging 4 sampling values.
D4 =
S1 + S2 + S3 + S4
4
, D5 =
S2 + S3 + S4 + S5
4
,
D6 =
S3 + S4 + S5 + S6
4
, D7 =
S4 + S5 + S6 + S7
4
,
D8 =
S5 + S6 + S7 + S8
4
Содержание KRN1000 SERIES
Страница 1: ... Copyright Reserved KONICS Co Ltd i USER MANUAL ...
Страница 2: ...ii Copyright Reserved KONICS Co Ltd ...
Страница 8: ...Safety Precautions viii Copyright Reserved KONICS Co Ltd ...
Страница 16: ...1 Product Introduction 16 Copyright Reserved KONICS Co Ltd ...
Страница 22: ...3 Dimensions 22 Copyright Reserved KONICS Co Ltd ...
Страница 39: ...6 Screen Copyright Reserved KONICS Co Ltd 39 English small letters Signs and numbers Number virtual keyboard ...
Страница 85: ...9 Troubleshooting Copyright Reserved KONICS Co Ltd 85 ...
Страница 86: ...9 Troubleshooting 86 Copyright Reserved KONICS Co Ltd KUM E 0180C_20160923 ...