E-3
(4) Secure the PI-506. (TP screws M4x6: 3 pcs.)
5. Install the wire bundle cover /1 to the PI-506
connector. (Truss screw M4x6 (black): 1 pc.)
6. Install the screw cover on the top front of the Fin-
isher.
7. Install the Finisher on the main body (refer to the
Finisher Installation manual).
8. Plug in the power cord and turn the Main power
switch ON of the main body.
9. Adjusting the spread of the paper-width guide
15JFIXE011SA
Connector
TP screws M4x6
A10YIXC002CA
Front
TP screws M4x6
15JFIXE014SB
Truss screw
M4x6 (black)
Wire bundle cover/1
Screw cover
Step
1. Enter [Service mode].
Note:
Refer to procedures in the Service Manual
to enter into the Serivce Mode.
2. Touch the “Finisher Adjustment” key.
3. Touch the “Cover Sheet Size Adj.” key to
indicate the [Cover sheet tray size adj.
(upper tray)] screen.
4. Set A4S or 8.5/11S paper in the upper
cover-sheet tray.
5. Touch the “Start” key.
6. When adjustment is completed, “Complete”
appears on the message display.
7. Touch the “Next” key to indicate the [Cover
Sheet Tray Size Adj. (Lower Tray)] screen.
8. Set A4S or 8.5/11S paper in the lower cover-
sheet tray.
9. Touch the “Start” key.
10. When adjustment is completed, “Complete”
appears on the message display.
11. Verify that each paper size can be properly
detected.