Trouble code
FS-501 Field Service Ver2.0 Sep. 2004
4-10
IV
T
rou
b
lsh
oot
in
g
2.3.2
C0B30:CD Aligning Motor (M5-FN) drive malfunction
A. Detection timing
B. Action
Malfunction code
Description
C0B30
The CD Aligning Home Position Sensor (PC9-FN) does not go LOW even after the
lapse of a given period of time after M5-FN has been energized (to return the Align-
ing Plate to its home position).
Relevant electrical parts
CD Aligning Home Position Sensor (PC9-FN)
CD Aligning Motor (M5-FN)
Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor and sensor connectors
for proper connection, and correct as
necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PC9-FN I/O, sensor check
PWB-A FN PJ25A FN-6
I-2
4
Turn OFF the Power Switch, move the
Aligning Plate out of its home position,
and turn ON the Power Switch. Opera-
tion check of the CD aligning Motor (M5-
FN) at this time.
-
A-6
5
PWB-A FN replacement
-
E-5
Содержание FS-501
Страница 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 501 THEORY OF OPERATION ...
Страница 2: ......
Страница 4: ......
Страница 6: ...FS 501 Theory of Operation Ver2 0 Sep 2004 ii I Outline II Composition Operation ...
Страница 10: ...Product specification FS 501 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Страница 30: ...Mechanical operations FS 501 Theory of Operation Ver2 0 Sep 2004 2 20 II Composition Operation Blank page ...
Страница 31: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 501 ...
Страница 32: ......
Страница 34: ......
Страница 46: ...Other FS 501 Field Service Ver2 0 Sep 2004 2 4 I General II Maintenance Blank page ...