Personal Computer
Accessory Case
CM-A209
Dust Cover
CM-A110
(CM-3600d)
CM-A118
(CM-3610d)
Opacity Jig
CM-A134
(only CM-3610d)
Spectrophotometer CM-3600d/CM-3610d
Standard accessories
Optional accessories
Target Mask
CM-A105
( 25.4mm)
AC Adapter AC-A12
AC Adapter AC-A21
(for Korea)
RS-232C Cable IF-A12
(9-pin, 2m)
White Calibration Plate CM-A103
(with containing calibration data)
Target Mask
CM-A106
( 8mm)
Target Mask
CM-A107
( 4mm)
Cell
CM-A99
(20mm)
Cell
CM-A98
(10mm)
Cell
CM-A97
(2mm)
Plastic Cell
CM-A132
(20mm; set for 100)
Plastic Cell
CM-A131
(10mm; set for 100)
Plastic Cell
CM-A130
(2mm; set for 100)
only CM-3600d
Transmittance.
Zero Calibration Plate
CM-A100
Transmittance
Specimen Holder
CM-A96
Zero Calibration Box
CM-A104
(CM-3600d)
Zero Calibration Box
CM-A119
(CM-3610d)
RS-232C Cables IF-A13
(9-pin, 5m)
Color Tiles
SpectraMagic
TM
NX
CM-S100w
System
Diagram
Specifications
Network construction for color control either within
an organization or between organizations
Built for Precision,
Priced for Economy
Outstanding Performance through Innovative Technology
CM-3600d Horizontal Spectrophotometer
Highly accurate, reliable and rugged
Versatile instrument for most colorimetric applications
Simplified operation.
CM-3610d Vertical Spectrophotometer for best application support
Speeds up textile and paper measurements
Ideal for non contact measurements such as powders, pigments
Quick sample handling and observation
In-house color control
Color control between companies
R&D
Design
Production
Company
A
Company
B
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series
CM-3600d
CM-3610d
CM-3500d
CM-2600d/2500d/2500c
"State of the Art" Reference models
Laboratory and Production Model(horizontal)
Laboratory and Production Model(vertical)
Unique Top Port bench-top model
Top class accuracy portables
CM-3500d
CM-3700d
CM-2000
/
2600d
series
2500d
CM-3600d
CM-3610d
High inter-instrument agreement between the same Konica Minolta
model and also among all CM models (benchtops and portables):
CM-2000 series, CM-3000 series,
This inter-instrument agreement is ideal when multiple units will be
used for color control either within an organization or between
organizations.
Weight
Size (W x H x D)
Storage temperature/
humidity range
Operating temperature/
humidity range (*1)
Power
Interface
Transmittance
chamber
UV cut filter
UV adjustment
Temperature
dependence
Inter instrument
agreement
Repeatability
Measurement/
illumination area
Minimum interval
Between measurements
Measurement time
Light source
Sphere size
Reflectance range
HaIf bandwidth
Wavelength pitch
Wavelength range
Illumination/
Observation system
Light-receiving element
Spectral separation
device
CM-3600d 12 kg, CM-3610d 16.5 kg
CM-3600d 244 x 208 x 378 mm, CM-3610d 300 x 597 x 315 mm
0 to 40
°
C, relative humidity 80% or less (at 33
°
C) with no condensation
13 to 33
°
C, relative humidity 80% or less (at 33
°
C) with no condensation
AC120V/230V 50/60Hz (Using included AC adapter)
RS-232C, D-SUB 9-pin (female) terminal
Width: 133mm; depth: approx. 50mm; measurement dia.: approx. 17mm
Transmission sample holder (Optional accessory): Sample holder
for both plate-shaped and liquid samples (removable)
400nm cutoff and 420nm cutoff
Instantaneous numerical adjustment
Spectral reflectance: Within
±
0.10%/
°
C
Color difference: Within
∆
E*ab 0.05/
°
C
Mean
∆
E*ab0.15 (SCI) Average for 12 BCRA Series II color tiles
compared to values measured with master body.
Spectral reflectance: Standard deviation within 0.1%
Colorimetric values: Standard deviation within
∆
E*ab0.02
LAV : ø25.4mm/ø30mm
MAV : ø8mm/ø11mm
(Selectable)
SAV : ø4mm/ø7mm
Approx. 5 seconds
Approx. 1.5 seconds
4 pulsed xenon lamps
ø152mm
0 to 200%; resolution: 0.01%
Approx.10nm
10nm
360 to 740nm
Reflectance; di:8
°
, de:8
°
(diffused illumination, 8-degree viewing), equipped with
simultaneous measurement of SCI (specular component included) / SCE (specular
component excluded) Conforms to CIE No.15,lSO7724/1,ASTME1164, DIN5033
Teil7 and JIS Z8722 condition C standard. Transmittance : di:0
°
, de:0
°
(diffused
illumination, 0-degree viewing) Conforms to CIE No.15, ASTME1164 and DIN5033
Teil7 standard.
Silicon photodiode array (dual 40 elements)
Diffraction grating
*1 Operating temperature/humidity range of products for North America : 13 to 33
°
C, relative humidity 80% or less (at 31
°
C) with no condensation
Mac OS 10.3.9J illustrator 10J
CM-3600d/3610d_outside.ai 2007.7.6
SAFETY PRECAUTIONS
Always connect the instrument to the
specified power supply voltage.
Improper connection may cause a
fire or electric shock.
AHIEPK
Printed in Japan
9242-4868-31
2000 KONICA MINOLTA SENSING, INC.
11
For correct use and for your safety, be sure to read
the instruction manual before using the instrument.
Certificate No : JQA-E-80027