3-3
Adjustment flow when changing the screen
)
Adjustment timing
-
When you change the setting of Custom Screen
)
Adjustment order
* When the changed Custom Screen is [Stochastic], Density balance adjustment is not required.
Tips
-
If you interrupted the operation during the adjustment flow, be sure to perform Gamma Automatic Adjustment
before the rest of adjustment flow.
-
The default setting of Color Centro is "Exact Color". When you want to change to "G7 Calibration", contact your
service representative. When you want to return "G7 Calibration" to "Exact Color", also contact your service
representative.
Reference
For details of each adjustment item, refer to "Contents of the image quality adjustment items" (
Page 3-4
).
Order
Adjustment item
Required time
Reference
1
Change setting of Custom Screen
Approximately
1 minute
P.3-4
2
Gamma Automatic Adjustment
Approximately
1 minute
P.3-6
3
Density Balance Adjustment *
Approximately
10 minutes
P.3-7
(for
i1Pro/i1Pro2/ES-
1000/ES-2000)
P.3-16
(for FD-5BT)
4
Color Density Manual Control
Approximately
1 minute
P.3-31
5
"Exact Color" or "G7 Calibration"
Approximately
25 minutes
P.3-33
(Exact Color)
P.3-39
(G7 Calibration)