Dr
u
m
u
nit/K, Ozone filter, Toner filter replacement instr
u
ctions
2
3.
Loosen the sho
u
lder screw [1], and
p
u
ll o
u
t the dr
u
m
u
nit/K [2].
4.
Hold the fixed lever [1] for the dr
u
m
u
nit/K at two positions, and remove
the dr
u
m
u
nit/K [2] while loosening
the fixed lever.
1.2
Reinstall procedure
1.
Remove the new dr
u
m
u
nit/K from
the black protective bag.
2.
Remove caps [1] at the front and the
back of the dr
u
m
u
nit/K.
A0P0F2C523DA
[2]
[1]
A0P0F2C524DA
[2]
[1]
[1]
A0P0F2C525DA
[1]
[1]