![Konica Minolta BIZHUB 164 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/konica-minolta/bizhub-164/bizhub-164_service-manual_1992961084.webp)
Theory of Operation
V
er. 1.1 Apr. 2010
19. FUSI
N
G SECTIO
N
53
bizhub 164
COMPOSITION/
OPERA
TION
19.3.3
Fusing temperature control
• The fusing heater lamp is turned on and off to keep a set temperature on the surface of
the Fusing Roller.
• The fusing roller surface temperature is detected by using a thermistor that translates the
temperature to a corresponding electrical signal.
• If the fusing roller temperature becomes excessively high, the fusing roller heater lamp is
shut down.
[1]
During warm-up cycle
[3]
During a print cycle
[2]
In standby state
[4]
In standby state
A0XXT2C536AA
[1]
200
[2]
[3]
[4]
Typical changes in temperature during an ordinary print cycle carried out after power is turned O
N
Temperature at which print request is acceptable