Konica Minolta AUTOREFLEX A Скачать руководство пользователя страница 9

WATCHING METER IN VIEWFINDER

Correct Exposure Range:

The stopping of the Meter Needle #2 within the range of correct exposure (or somewhere on the f-

number scale for the used lens) is an indication of the feasibility of taking pictures under the Electric-Eye system. Here, the

meter needle shows the aperture to which the taking lens is to be set for a shot.

Warning Marks and Mark for the Indication of Fnumber at the Full Opening of the Lens:

The red mark visible on the top

of the f-number scale visible in the field of view is a mark for the warning of underexposure for an f/1.2 lens. If the lens is not f/

1.2 in brightness, the Mark for the Indication of the F-Number at the Full Lens Opening (43) will show the f-number at the full

opening of the taking lens. If the meter needle is aligned with this mark, pictures will be under-exposed. The signal placed at the

bottom of the f-number scale is a warning mark for over-exposure. If the meter needle is brought in line with this Over-exposure

Warning Mark 40, it will be impossible to secure a correct exposure.

Index Point for Stopped-Down Aperture Measurement :

When the lens is stopped down for the measurement of light the meter needle will be aligned with the Index Point 39, if a

combination of shutter speed and lens aperture which assures correct exposure for the film used in the camera comes out.

Manual Aperture Indicator Mark: "M", the Manual Aperture Indicator Mark 44,, indicates the non-alignment of the Electric Eye

Mark 

I~ 

of the Aperture Ring 12 with the index mark for a fully automatic aperture (Electric-eye) lens. When the camera is not

used under the Electric-eye system, the alphabet "M" is visible at all times, indicating that the aperture of the lens may be

manually operated.   This manual was created by www.butkus.org/chinon and should only be found at my site.

LIGHT MEASUREMENT AT FULL LENS OPENING

ELECTRIC-EYE PHOTOGRAPHY

(Light Measurement at Full Lens Opening)

In the event that a lens equipped with a fully automatic aperture under the Electric-Eye system and having an Electric-Eye mark,

pictures may be taken under the Electric-Eye system while light is measured at the full opening of the lens and the viewfinder is

brightened as a result of its full opening.

Содержание AUTOREFLEX A

Страница 1: ...22 Electric Eye Photography 24 Meter s Coupling Range 26 Important Points for Light Measurement at Full Lens Opening 28 Training of Camera 30 Focusing 32 Depth of Field 34 Infrared Film Compensation M...

Страница 2: ......

Страница 3: ...ve compound CdS meter light measured mostly at center of picture image Automatic aperture lens Electric eye Full electric eye system coupled to film speed shutter speed and interchangeable lenses at f...

Страница 4: ...ble for more than one year if used normally The battery voltage drops abruptly when it becomes weak the CdS meter will stop normal operation When the meter pointer does not move even in bright light r...

Страница 5: ...pool 34 Any slit is usable Choose any slit into which the film tip can be inserted with ease 141 Turn the Film Cocking Lever 17 and take up the film on the spool Ascertain that the teeth of the Sprock...

Страница 6: ...es one reading indicating the number of pictures that have been taken When the back cover is opened after the exposure of a roll of film the film counter automatically returns to the S Start position...

Страница 7: ...he full opening at once TTL METERING AND FULLY AUTOMATIC CONTROL The KONICA AUTOREFLEX A incorporates the latest exposure system in which the compound CdS meter which measures at the center of the tak...

Страница 8: ......

Страница 9: ...l be impossible to secure a correct exposure Index Point for Stopped Down Aperture Measurement When the lens is stopped down for the measurement of light the meter needle will be aligned with the Inde...

Страница 10: ...The figures in brackets are the readings for intermediate film speeds 1 Set the film speed ASA or DIN Lift and turn the external ring of the Shutter Speed Dial 8 and align the reading equivalent to t...

Страница 11: ...osure is recognized by the meter needle select slow shutter speed Whereas in over exposure obtain fast shutter speed In case the meter is within a correct exposure range it allows making EE photograph...

Страница 12: ...tically than to hold it horizontally It would be advisable to get yourself accustomed to the vertical holding of the camera because there are many cases in which the camera must be trained vertically...

Страница 13: ...t but also a certain area around the subject will be sharply delineated in a photograph and this area is known as a depth of field and has the following features 1 The larger the f number the bigger t...

Страница 14: ...e focusing ring to bring this reading in line with the Infrared Film Compensation Mark 47 before the shutter button is depressed for a shot This manual was created by www butkus org chinon and should...

Страница 15: ...mark and the shutter will be opened during the time when the shutter button is kept depressed and it will be closed once the finger is separated from the button This process is usable when there is t...

Страница 16: ...II on which either a synchroflash gun or a small electronic light unit may be mounted As your camera is equipped with a tap hole each for Classes M and X insert the plug into the Synchroflash Contact...

Страница 17: ...of guide numbers is available depending on the synchroflash gun Here use this table LENS INTERCHANGE To dismount the lens To dismount the lens depress the Lens Interchanging Button 4 when the silver p...

Страница 18: ...ome in line with the Index Mark 39 visible in the viewfinder Correct exposure is assured when the meter needle is aligned with the index mark Focus the lens and frame the subject before the shutter bu...

Страница 19: ...perture before the ring is turned to secure a correct exposure In the event that the subject is moving so fast that there is the need for quick photographing actions exposure may be determined by simu...

Отзывы: