Chapter 5 Disassembly and Assembly
5-19
5.3
Replacing the Parts on the Insertion Unit
5.3.1 Replacing the Operation Unit (Operation Panel)
This section describes the instructions on how to replace the operation unit. Following are the procedures
available for the unit with the horizontal positioning, though the same procedures can be used for the unit
with the vertical positioning.
Work outline
Listed below are the number of people and the rough standard of work hours required for performing the
works described in this section.
Requirements
The works in this section can be performed using only the standard tools.
1
Removal Procedures (Page 5-6)"
"5.2.3 Removing/Installing the Exterior Panel and
to remove the insertion unit.
Reverse the removed insertion unit and place it in a stable place in order to perform the replacing work.
2
Remove the operation unit.
•
4 tapping screws (M4 x 10)
3
Unplug a cable from the operation unit.
•
Connector (OCN1)
4
Connect the cable to the new operation unit.
5
See
to install the operation unit.
•
4 tapping screws (M4 x 10)
6
Installation Procedures (Page 5-8)"
"5.2.3 Removing/Installing the Exterior Panel
to install the insertion unit and exterior panel.
Now, you have finished with the procedures to replace the operation unit.
Caution
Be sure to turn off the power supply circuit breaker and unplug the power cable from the
equipment whenever you disassemble/assemble the equipment.
Personnel
Number
Work Hours (steps 2 to 5)
1
OCN1
Caution
When removing the connector, hold a notch
on the connector without pulling a cable.
Giving a strong pull to the cable may cause
it to be broken.
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......