423852/B
25
Overview of frequency
selection
If many acoustic systems are used simultaneously, due care must be taken to prevent
acoustic interference between the different instruments.
Simrad catch monitoring sensors communicate on a frequency range from 40 to 50 kHz.
Frequencies
(kHz)
39.4 -
40.7
40.8 -
42.1
42.2 -
43.5
43.6 -
44.9
45.0 -
46.3
46.4 -
47.7
47.8 -
49.1
49.2 -
50.5
PX TrawlEye
Channel
1
2
3
4
5
6
7
8
PX Sensors
Channel
1L
1H
2L
2H
3L
3H
4L
4H
5L
5H
6L
6H
7L
7H
8L
8H
PI Sensors
Channel
—
—
—
—
—
—
1 - 30
—
SR15 and SR70 Receiver Units
• Frequency range: 39.4 — 50.5 kHz.
• An SR type receiver has 8 communication channels when interfacing the following
sensor/sensors:
– PX TrawlEye
• An SR type receiver has 16 communication channels (1 Low to 8 High) when interfacing
the following sensor/sensors:
– PX MultiSensor Mk2
– PX MultiCatch
– PX Universal
– PX Flow