342741/B
61
Cable gland procedure
Cable glands are used whenever a cable passes through a water-tight bulkhead or into a
cabinet, to seal the opening through which the cable passes and to protect the cable from
abrasion on the edges of the hole. Follow the guidelines detailed here when installing
cables through cable glands.
Prerequisites
Ensure that all the cables to be connected are completely isolated from any power
sources.
Verify that no safety interlocks have been bypassed. A minimum of 5 to 10 cm of slack
cable must be allowed (depending on the cable diameter and arrangement), both inside
and outside the cabinet, when installing cables.This is to allow for vibration damping,
maintenance and measurement errors. Always double-check your measurements before
taking any irreversible actions.
With a steel conduit the installation will satisfy the European Union regulations for
electromagnetic compatibility (EMC) interference. Without a steel conduit, there is
a risk of reduced performance.
Context
Note
The screen in cables must never be connected to ship’s ground in the cable glands!
Tag out the system properly.
Procedure
1
Select the cable to be connected, and select the cable gland to use. Make sure you
use the correct size cable gland according to the cable size. The cable glands are
included in the delivery.
2
Slacken and remove the compression nut from the cable gland, and extract the
compression seal and the screen collar from the body of the gland.