Ethernet cable with RJ45
This cable is used to provide standard Ethernet connections. Note that various categories
exists.
Cat.5 E
and
Cat.6
cables are used in local area networks with date rate exceeding
100 Mbit/s.
Ethernet cables are available commercially in different lengths, colours and categories.
Pairs
Pairs
RJ45 plug
RJ45 plug
RJ45 plug
Ethernet 10Base-T
“
Straight Through
”
Ethernet 10Base-T
“
Crossover
”
The
“
crossover
”
cable is used to cascade HUBs,
or for connecting two ethernet stations or
computers back-to-back without a HUB)
TX Data + (White/Orange)
(1) TX Data + to (3) Recv Data +
Tx Data - (Orange)
(2) Tx Data - to (6) Recv Data -
Recv Data + (White/Green)
(3) Recv Data + to (1)
Tx Data +
(Blue)
(White/Blue)
Recv Data - (Green)
(6) Recv Data - to (2)
Tx Data -
(White/Brown)
(Brown)
RJ45 plug
Pin 8
Pin 1
View
Pin 1
Pin 8
End view
of RJ45 plug
1
3
2
4
5
7
6
8
1
3
2
4
5
7
6
8
1
3
2
4
5
7
6
8
1
3
2
4
5
7
6
8
W400
Rev.F
Ethernet 10Base-T
with RJ45 plugs
Screened category 6 (or 5 E) twisted pair cable to fit the specific RJ45 connectors used.
AWG 23 and 24 size conductors are recommended.
317669/B
141
Содержание EM 122
Страница 1: ...EM 122 Multibeam echo sounder Installation Manual...
Страница 2: ......
Страница 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Страница 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Страница 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Страница 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Страница 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Страница 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Страница 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Страница 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Страница 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Страница 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Страница 97: ...Cable layout and interconnections Figure 40 EM 122 Transceiver Unit s rear panel RX 317669 B 95...
Страница 126: ...EM 122 Figure 57 Cable layout 0 5 degree TX page 1 of 2 Cd021 106 Page 1 of 2 315396 Pro03 124 317669 B...
Страница 127: ...Drawing file Figure 58 Cable layout 0 5 degree TX page 2 of 2 Cd021 106 Page 2 of 2 315396 Pro03 317669 B 125...
Страница 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Страница 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Страница 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Страница 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Страница 154: ...2013 Kongsberg Maritime...