Страница 1: ...429468 B October 2020 Kongsberg Maritime AS cNODE Embed Instruction Manual ...

Страница 2: ... was designed Improper use or maintenance may cause damage to the equipment and or injury to personnel You must be familiar with the contents of the appropriate manuals before attempting to operate or work on the equipment Kongsberg Maritime disclaims any responsibility for damage or injury caused by improper installation use or maintenance of the equipment Disclaimer Kongsberg Maritime AS endeavo...

Страница 3: ...pinout J1 15 Power connector J4 16 Service connector J5 17 GENERAL ACOUSTIC CONSIDERATIONS 18 OPERATING PROCEDURES 20 SPARE PARTS 21 TD180 Spare part 22 TD80V Spare part 22 Printed Circuit Board PCB Spare part 22 Capacitor Spare part 22 Transformer TD180 Spare part 22 Transformer TD80V Spare part 23 Cable kit Spare part 23 TECHNICAL SPECIFICATIONS 24 Performance specifications 25 Weight and outlin...

Страница 4: ...4 429468 B cNODE Embed TD180 wiring diagram 33 cNODE Embed ...

Страница 5: ...user manuals provided for operation and installation of your cNODE Embed can be downloaded from our website https www kongsberg com maritime Registered trademarks Observe the registered trademarks that apply Windows is a registered trademark of Microsoft Corporation in the United States and other countries HiPAP is a registered trademark of Kongsberg Maritime AS in Norway and other countries cNODE...

Страница 6: ...6 429468 B Kongsberg cNODE Embed Topics System description page 7 Scope of supply page 7 General supply conditions page 7 Support information page 8 cNODE Embed Instruction Manual ...

Страница 7: ...y 20 kHz to 30 kHz band and both FSK and Kongsberg Cymbal navigation codes are available Cymbal wide band offers 560 unique navigation codes and range accuracies of better than 2 cm are achievable Scope of supply The main units required are provided with the standard delivery Printed Circuit Board PCB Transducer Transformer Cable kit Optional Quick Reference Guide General supply conditions General...

Страница 8: ...ipment must be covered to protect it from dust and other forms of contamination when stored Support information Should you need technical support for your cNODE Embed you must contact a Kongsberg Maritime office A list of all our offices is provided on our website You can also contact our main support office in Norway Manuals and technical information can be downloaded from our support website Com...

Страница 9: ...bles Topics About Electrostatic Discharge ESD page 10 Installing the cNODE Embed cables page 11 Installing the transducer cables TD180 page 12 Installing the transducer cables TD80V page 13 Connectors page 15 Installing the cNODE Embed cables ...

Страница 10: ...aused either by direct contact or induction by an electrostatic field The passing of a charge through an electronic device can cause local overheating and it can also puncture insulating layers within the structure of the device This may deposit a conductive residue of the vaporized metal on the device and thus create a short circuit Electrostatic Discharge ESD may result in a failures or degraded...

Страница 11: ...nnected to the service mat 3 Printed circuit boards and electronic modules must be placed on the conductive service mat during installation and maintenance operations 4 If for any reason it is necessary to move the circuit board from the conductive service mat it must be placed in an approved antistatic transportation container for example a static shielding bag before transportation 5 During inst...

Страница 12: ...res 8 Install the crimp terminals in a Molex 10 pin receptacle according to the cable drawing Service connector J5 page 17 This is now connector J5 9 Connect J5 to P5 in the front on the PCB Installing the transducer cables TD180 The cables can be provided with an optional cable kit Prerequisites Transducer connector pinout J1 page 15 The following specific items are required for this task 1 x Mol...

Страница 13: ...ll the crimp terminals in a Molex 8 pin receptacle according to the cable drawing a Connect the green wires to pin 1 and 5 on the receptacle b Connect the black wires to pin 3 and 7 on the receptacle c Connect the blue wires to pin 4 and 8 on the receptacle d Connect the orange wire to pin 6 on the receptacle This is now receptacle J1 9 Connect receptacle J1 to connector P1 on the front of the PCB...

Страница 14: ...former 5 Use two green wires 0 24 mm2 and connect both to the green wire from the transducer 6 Use one orange wire 0 24 mm2 and connect to the orange wire from the transducer 7 Add crimp terminals to the end of the wires 8 Install the crimp terminals in a Molex 8 pin receptacle according to the cable drawing a Connect the green wires to pin 1 and 5 on the receptacle b Connect the black wires to pi...

Страница 15: ...number Colour Signal Minimum requirements 1 Green ID data 0 24 mm2 2 Screen 3 Black TD 0 5 mm2 4 Blue TD 0 5 mm2 5 Green ID data 0 24 mm2 6 Orange Ground 0 24 mm2 7 Black TD 0 5 mm2 8 Blue TD 0 5 mm2 Related topics Installing the transducer cables TD80V page 13 Installing the transducer cables TD180 page 12 Installing the cNODE Embed cables ...

Страница 16: ...uration for a female plug as seen towards the plug face view Pin number Colour Signal Minimum requirements 1 Red External power 24 VDC 0 5 mm2 2 Red External power 24 VDC 0 5 mm2 3 Black Ground 0 5 mm2 4 Black Ground 0 5 mm2 cNODE Embed Instruction Manual ...

Страница 17: ...ug as seen towards the plug face view Pin number Signal Minimum requirements 1 Not connected 2 Not connected 3 Not connected 4 Ground 0 5 mm2 5 Not connected 6 Not connected 7 Not connected 8 Not connected 9 RS 232 Tx 0 5 mm2 10 RS 232 Rx 0 5 mm2 Installing the cNODE Embed cables ...

Страница 18: ...transducers used on the transponders An omnidirectional transducer such as TD180 covers a large area but has less acoustic power compared to a focused transducer such as TD30V A focused signal gives less footprint coverage The vessel should always be within the signal footprint of the transponder Tx Power The ability to detect signals depends on the signal strength The transmission power can be ad...

Страница 19: ...and ray bending Changes in sound velocity through the water column caused by changes in the water temperature and or salinity can bend the acoustic signal and make it impossible to reach the vessel General acoustic considerations ...

Страница 20: ...20 429468 B Operating procedures The transponder is operated from the HiPAP operator station APOS Refer to APOS online help for descriptions cNODE Embed Instruction Manual ...

Страница 21: ...80 Spare part page 22 TD80V Spare part page 22 Printed Circuit Board PCB Spare part page 22 Capacitor Spare part page 22 Transformer TD180 Spare part page 22 Transformer TD80V Spare part page 23 Cable kit Spare part page 23 Spare parts ...

Страница 22: ...t number 350501 Printed Circuit Board PCB Spare part Part name cNODE Embed Printed Circuit Board PCB Part number 423908 Capacitor Spare part Part name cNODE Embed Capacitor Part number 212 076626 Transformer TD180 Spare part Part name Transformer TD180 Part number 412432 cNODE Embed Instruction Manual ...

Страница 23: ...nsformer TD80V Part number 402399 Cable kit Spare part The cable kit contains the following items Receptacle J1 with 150 mm wires Receptacle J4 with 150 mm wires Receptacle J5 with 150 mm wires Part name cNODE Embed Cable kit Part number 430973 Spare parts ...

Страница 24: ...29468 B Technical specifications Topics Performance specifications page 25 Weight and outline dimensions page 26 Power requirements page 27 Environmental requirements page 27 cNODE Embed Instruction Manual ...

Страница 25: ...1 31 kHz Responder trigger signal 5 25 V positive logic pulse 2 6 ms Depth rating 3000 m Internal tilt sensor 90 TD80V Transducer beam 80 Vertical Receiver sensitivity 85 dB Source level Maximum 188 dB High 182 dB Low 176 dB Minimum 171 dB TD180 Transducer beam 180 Receiver sensitivity 100 dB Source level Maximum 190 dB High 184 dB Low 178 dB Minimum 173 dB Technical specifications ...

Страница 26: ...em Printed Circuit Board PCB Outline dimensions Height 142 mm Width 63 mm Depth 22 mm TD80V Outline dimensions Height 57 7 mm Diameter 68 mm TD180 Outline dimensions Height 70 5 mm Diameter 88 mm Capacitor Outline dimensions Height 18 mm Width 5 mm Depth 10 5 mm Transformer Outline dimensions Height 32 mm Diameter 42 mm cNODE Embed Instruction Manual ...

Страница 27: ...tage requirement 22 5 29 5 VDC Nominal voltage 24 VDC Transmit power 250 W Standby power 100 mW Environmental requirements These specifications summarize the temperature requirements and other environmental standards for the cNODE Embed system Operating temperature 5 to 55 C Storage temperature 30 to 70 C Technical specifications ...

Страница 28: ...le Topics TD80V Outline dimensions page 29 TD180 Outline dimensions page 30 PCB Outline dimensions page 31 cNODE Embed TD80V Low wiring diagram page 32 cNODE Embed TD180 wiring diagram page 33 cNODE Embed Instruction Manual ...

Страница 29: ...429468 B 29 TD80V Outline dimensions Drawing file ...

Страница 30: ...30 429468 B TD180 Outline dimensions cNODE Embed Instruction Manual ...

Страница 31: ...429468 B 31 PCB Outline dimensions Drawing file ...

Страница 32: ...32 429468 B cNODE Embed TD80V Low wiring diagram cNODE Embed Instruction Manual ...

Страница 33: ...429468 B 33 cNODE Embed TD180 wiring diagram Drawing file ...

Страница 34: ...spare part 22 caution ESD electrostatic discharge 10 characteristics performance 25 connector pin out 15 17 signal pin number 15 17 D description system 7 dimensions technical specifications 26 documents download from website 5 download documents from website 5 E electrostatic discharge ESD about 10 caution 10 preventing 11 what is it 10 environmental requirements 27 equipment handling 7 receipt 7...

Страница 35: ...tal 27 power 27 temperature 27 S scope of supply basic items 7 size technical specifications 26 spare part cable kit 23 capacitor 22 PCB 22 TD180 22 TD80V 22 transformer 22 23 specifications outline dimensions 26 performance 25 weight 26 standard items provided with the delivery 7 storage general supply conditions 7 supply conditions receipt 7 storage 7 unpacking 7 support information 8 system des...

Страница 36: ...36 429468 B W website download documents 5 weight technical specifications 26 what is electrostatic discharge ESD 10 wiring prerequisites 11 13 cNODE Embed Instruction Manual ...

Страница 37: ......

Страница 38: ... 2020 Kongsberg Maritime ...

Отзывы: