Use 

The hood is designed to be used either for exhausting or filter 
version. 
  

 Ducting version

 

In this case the fumes are conveyed outside of the building by 
means of a special pipe connected with the connection ring 
located on top of the hood. 

Attention

! The exhausting pipe is not supplied and must be 

purchased apart. 
Diameter of the exhausting pipe must be equal to that of the 
connection ring. 
In the horizontal runs the exhausting pipe must be slightly 
slanted (about 10°) and directed upwards to vent the air easily 
from the room to the outside. 
Attention! If the hood is supplied with active charcoal filter, 
then it must be removed. 

Connect the hood and discharge holes on the walls with a 
diameter equivalent to the air outlet (connection flange). 
Using the tubes and discharge holes on walls with smaller 
dimensions will cause a diminution of the suction performance 
and a drastic increase in noise. 

Any responsibility in the matter is therefore declined.  

Use a duct of the minimum indispensible length. 

Use a duct with as few elbows as possible (maximum 
elbow angle: 90°). 

Avoid drastic changes in the duct cross-section. 

Use a duct as smooth as possible inside. 

The duct must be made of certified material. 

  

 Filter version

 

One active charcoal filter is needed for this and can be 
obtained from your usual retailer.  
The filter removes the grease and smells from the extracted 
air before sending it back into the room through the upper 
outlet grid. 

 

Installation 

The minimum distance between the supporting surface for the 
cooking equipment on the hob and the lowest part of the 
range hood must be not less than 50cm from electric cookers 
and 65cm from gas or mixed cookers. 
If the instructions for installation for the gas hob specify a 
greater distance, this must be adhered to. 

 

  Electrical connection 

The mains power supply must correspond to the rating 
indicated on the plate situated inside the hood. If provided with 
a plug connect the hood to a socket in compliance with current 
regulations and positioned in an accessible area, after 
installation. If it not fitted with a plug (direct mains connection) 
or if the plug is not located in an accessible area, after 
installation,  apply a double pole switch in accordance with 
standards which assures the complete disconnection of the 
mains under conditions relating to over-current category III, in 
accordance with installation instructions. 

Warning!

 Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 
the mains cable is correctly assembled. 

Warning! 

Power cable replacement must be undertaken  by 

the authorised service assistance centre or similar qualified 
person. 

 

Mounting 

Expansion wall plugs are provided to secure the hood to most 
types of walls/ceilings. However, a qualified technician must 
verify suitability of the materials in accordance with the type of 
wall/ceiling. The wall/ceiling must be strong enough to take 
the weight of the hood. 

Do not tile, grout or silicone this 

appliance to the wall. Surface mounting only. 

 

Additional Installation Specifications:  

Use only the fixing screws supplied with the product for 
installation.  
Use the correct length screws which are identified in the 
Installation Guide  

WARNING! 

Failure to install the screws or fixing device in 

accordance with these instructions may result in electrical 
hazards. 

 

Содержание NCR 60I

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ...ti dovoljno provjetravanje kada je kuhinjska napa upotrebljavana istovremeno s drugim aparatima na plinski pogon ili na drugo gorivo Zrak koji se usisava ne smije biti proveden u cijev koja se koristi...

Страница 9: ...a osnovi aktivnih karbonskih filtara Postavljanje Minimalna udaljenost izme u podloge za posude na ure aju za kuhanje i najni eg dijela kuhinjske nape ne smije biti ni a od 50cmkada se radi o elektri...

Страница 10: ...no e koje se stvaraju prilikom kuhanja Taj filtar morate istiti jednom mjese no upotrijebiv i neagresivne deterd ente bilo ru no ili u stroju za pranje posu a u kojem slu aju morate izabrati program p...

Страница 11: ...her fuels The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose such as discharging exhaust fumes from appliances bur...

Страница 12: ...e range hood must be not less than 50cm from electric cookers and 65cm from gas or mixed cookers If the instructions for installation for the gas hob specify a greater distance this must be adhered to...

Страница 13: ...fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Grease filter Fig 8 23 Traps cooking grease particles The grease filter must be cleaned once a mo...

Страница 14: ......

Отзывы: