Fig.7-19 Interface Diagram of Menu“Multi-traces Setting”   

7.7.2 Instruction of Button“Trace 1/2/3/4”   

Button  icons  in  the  trace  operation  area  are  valid  to  all  opened  traces  simultaneously. 

Current trace can be switched through the trace switching button or through clicking  “trace 1” 
(or “trace 2”, “trace 3”, “trace 4”) directly. The data in the info window is that of the current 
trace. 

7.7.3 Instruction of Button“Remove”   

The current trace can be removed. The trace can be removed from the displayed window 

through trace remove operation. The remove operation is only valid for the current trace. After 
remove  the  current  trace,  the  next  smallest  SN  trace  will  be  adjusted  to  be  the  current  trace 
automatically. 

7.7.4 Instruction of Button“Esc”   

The button“Esc”provides operation back to OTDR home page. Once clicking the button, 

any operation under multi-traces analysis will be cancelled and the setting won’t be saved. 

7.7.5 Instruction of Button“Help”   

The button“help”provides operation instruction under multi-waveform analysis. 

7.7.6 Instruction of Button“Home Page”   

When clicking the button“home page”, it will directly back to the home page interface of 

the instrument. 

Содержание OTDR QX50

Страница 1: ...Optical Time Domain Reflectometer KomShine QX50 OTDR User Manual...

Страница 2: ...the current operation effect Up down buttons Select the desired menu icon On the keyboard or drop down list select the corresponding characters or data In the folder tree structure window realize the...

Страница 3: ...with buttons can realize combination functions of transversal amplifying and reducing of trace On the home page of OTDR function module the button used together with button can realize the fast switc...

Страница 4: ...Main Interface of OTDR 18 7 1 3 Instruction of Info Window Area of the Main Interface of OTDR 19 7 1 4 Instruction of Status Bar Area on the Main Interface of OTDR 21 7 2 Instruction of Menu Button Se...

Страница 5: ...t of Multi traces Displaying File 48 8 5 3 Displaying Area of Measurement Parameter 48 8 5 4 Displaying Area of Measurement Result 48 8 6 Instruction of Event List Window of PC Terminal Software of OT...

Страница 6: ...e Any change of the information in the manual won t be notified We won t guarantee anything about the material including but not limited to hint guarantee for marketability and adaptability of dedicat...

Страница 7: ...he Manual Warning symbol indicates danger existed It informs users pay attention to a certain process a certain operation method or similar conditions If operate wrongly or violate rules bodily injury...

Страница 8: ...injured and corroded Outside power supply All OTDR series can use outside power supply Requirements of power supply DC12V 3A polarity Avoid laser radiation during measuring processing of optical fibe...

Страница 9: ...8 3 Appearance Diagram of OTDR Product Fig 3 1 Appearance Diagram of OTDR...

Страница 10: ...charging the battery the indicator is turned on to be green when charging finished the indicator will turn off automatically LAN Ethernet Interface Several models have such interface Audio Interface S...

Страница 11: ...y the current operation effect Up down buttons Select the desired menu icon On the keyboard or drop down list select the corresponding characters or data In the folder tree structure window realize th...

Страница 12: ...with buttons can realize combination functions of transversal amplifying and reducing of trace On the home page of OTDR function module the button used together with button can realize the fast switc...

Страница 13: ...TDR optical time domain reflectometer and VFL visual fault location Directly clicking OTDR or VFL can enter into the operation page of their functional modules As shown in the following figure 4 1 Ope...

Страница 14: ...x of auto turn off setting is ejected Operator can conduct corresponding setting on the dialog box Auto turn off function provides options of OFF after 5 min after 10 min after 30 min after 1 hour aft...

Страница 15: ...truction and monitoring of cable line It can measure the optical fiber length transmission attenuation of optical fiber attenuation of splice and failure location etc When the pulse being transmitted...

Страница 16: ...screen is the abnormal points in the optical fiber that led to deviation of trace which are classified with special symbols on the trace Events include reflection event and non reflection event 6 3 1...

Страница 17: ...OTDR sends optical pulse into the optical fiber that waited for inspection then begins to accept the returned optical signal immediately and calculate the distance of event in the optical fiber The fu...

Страница 18: ...roduction to Operation of OTDR 7 1 Instruction of Home Page Screen of OTDR The trace displayed on the screen that measured by OTDR is shown in Fig 7 1 Fig 7 1 Interface Diagram Displayed on the Screen...

Страница 19: ...lifying indicates longitudinally amplifying the measured trace with the intersection of the chosen sign post and the trace as center Longitudinal reducing indicates longitudinally reducing the measure...

Страница 20: ...e link length link loss link attenuation coefficient and quantity of event Definition and setting of file name duration of measurement and measurement date are shown in set menu When looking over info...

Страница 21: ...the last event point to the current event point Echo loss reflect the reflection value of the event point Accumulate loss indicates the loss value of optical fiber from the initial point to the curre...

Страница 22: ...of measurement starting and stopping and will prompt measurement status in the status bar of the measurement model Display of measuring progress status bar when clicking the icon button measurement OT...

Страница 23: ...10 Interface Diagram of Menu Set 7 2 1 Parameter Setting Fig 7 11 Interface Diagram of Menu Parameter Setting laser wavelength Distance scope pulse width duration of measurement measurement model ref...

Страница 24: ...role in the measurement Length unit meter No option or user setting is provided in OTDR instrument Refractivity set by user input scope 1 0000 1 9999 default value is set to be 1 4685 Back scattering...

Страница 25: ...le will be automatically named and set to ON status The auto naming category is optional Automatic storage file is the presence of SD card under the root directory when the OTDR is not inserted the SD...

Страница 26: ...Bundling threshold line selected by user options include ON and OFF the default value is OFF Bundling threshold line is marked with red dotted line Screen brightness adjustment selected by user option...

Страница 27: ...nated and warning prompt should be given Prompt mode warning dialog box ejects The accuracy of the data measured by OTDR instrument is closely related to the connection status of the connector of the...

Страница 28: ...imultaneously If the file setting is saving after finishing multi wavelength measurement click the menu icon saving to save the trace files When saving it will circularly prompt whether save the corre...

Страница 29: ...28 unfolded subfolders function through the enter button on the folder options and confirming function Fig 7 15 Interface Diagram of Menu Saving...

Страница 30: ...en will eject In the key mode of operation through the SHIFT button to achieve circular switching function for each window through the button to achieve the path choice of the folded or unfolded subfo...

Страница 31: ...er renaming file folder copying and file folder deletion can be fulfilled In the key mode of operation through the SHIFT button to achieve circular switching function for each window through the butto...

Страница 32: ...es Analysis 7 7 1 Instruction of Button Multi traces Setting Click the button icon multi traces setting in the multi waveform analysis dialog box multi traces setting will eject By clicking the icon b...

Страница 33: ...e displayed window through trace remove operation The remove operation is only valid for the current trace After remove the current trace the next smallest SN trace will be adjusted to be the current...

Страница 34: ...i e lock the current displayed trace in the trace graph area when clicking the button trace unlock the locking function is relieved Trace locking function can lock one trace each time The locked trac...

Страница 35: ...ton Help of OTDR After clicking the button help the table of contents will eject Contents looked over can be selected according the table of contents 7 10 Instruction of Menu Button Home Page of OTDR...

Страница 36: ...OTDR Traces Manager is as follows z Pentium 3 or Pentium 4 or private computer with similar configuration z Microsoft Windows98 2000 XP 7 operation system z Available space of hardware is larger than...

Страница 37: ...following several parts menu bar window toolbar window waveform window including trace graph multi waveform displaying file list measurement parameter measurement result event list window the whole wa...

Страница 38: ...ile save save as the current curve save all curves print the option print print preview batch modifying batch print multi traces print on single page display and print multi traces escape the applicat...

Страница 39: ...current curve save all curves save the current curve as When selecting save the current modified curve save all modified curve and save the current curve as another file the dialog box shown in Fig 8...

Страница 40: ...trace information trace graph including mesh sign post bundling threshold line event point marks thumbnail parameter information optical fiber link and event list Its default value option is trace in...

Страница 41: ...40 4 Batch Modifying Batch modifying only allows batch modifying of information in trace file under the same file folder as shown in Fig 8 7 Fig 8 7 Interface Diagram of Dialog Box Batch Modifying...

Страница 42: ...e display and print multi traces only allows print mode of trace file under the same folder a Batch print The print mode only allows print format of single trace in single page of trace file under the...

Страница 43: ...e 4 waveform page 6 waveform page or 8 waveform page needs to be selected firstly Each page setting corresponds to different formats In addition under the print mode the first selected trace file i e...

Страница 44: ...rinting trace files will display the corresponding figure and wave length information In addition under the print mode the first selected trace file i e the uppermost one is defined as the master file...

Страница 45: ...e trace information editing event increasing event modifying and event deleting Through trace information editing one can realize trace information modifying of the trace file through event increasing...

Страница 46: ...nsversal longitudinal amplifying reducing whole trace displaying displaying concealing of relevant tool buttons for AB scale plate AB line locking switching displaying concealing of relevant tool butt...

Страница 47: ...l Software Toolbar Window of OTDR Fig 8 14 Interface Diagram of Toolbar Window The toolbar window is under the menu bar window The purpose of toolbar window is to make the main functions under the men...

Страница 48: ...aph area as shown in Fig 8 16 The lateral axis represents the distance unit m while the vertical axis represents the back scattering power Unit dB The 11 icon buttons in the right of trace graph area...

Страница 49: ...hrough the right key of mouse functions of trace information opening closing and editing of a single file can be realized List of multi traces displaying file is as shown in Fig 8 17 Fig 8 17 Schemati...

Страница 50: ...ion quantity of the reflection event Accumulate loss indicating the attenuation dB value of the optical fiber from the connector of OTDR instrument and the optical fiber tested to the event Note note...

Страница 51: ...e needs to be wiped periodically with dedicated alcohol After using cover the dust cap meanwhile keep the cleanness of the dust cap In addition clean the connector of flange periodically There is no n...

Страница 52: ...ay attention to the follows You d better store the instrument including battery under room temperature 15 to 30 and place it at dry place to keep its best performance If the instrument is left unused...

Страница 53: ...ge caused from maintenance or treatment by unauthorized personnel or non our technicians z Anti dismounting labels are torn up z Serial number of the equipment is modified erased or worn z Equipment d...

Страница 54: ...guarantee scope user should pay the expense stated on the maintenance report If the equipment is within the guarantee scope we will pay the back freight To accelerate problem treatment process please...

Страница 55: ...ange the button board Problem 3 data saving aren t allowed Possible reason SD card is used up Solving method Export the curve to empty the memory z Optical fiber connection problem Improper optical fi...

Страница 56: ...fiber or the length that found by the automatic measurement model Problem 7 Only partial trace is displayed which causes test failed Possible reason The set testing distance is too short Solving metho...

Страница 57: ...66 Optical interface FC UPC PC and APC are selectable Weight 1 5kg Data interface USB interface SD card interface Running temperature 10 to 50 Temperature Memory temperature 40 to 70 Visible failure...

Страница 58: ...tion KomShine Technologies Limited Add 1F Building 2 Huashen Technology Park Yuhua district Nanjing JS 210012 P R China Call us 86 25 8687 1288 Fax us 86 25 8687 1388 e mail sales komshine com Website...

Отзывы: