3.4.3. Air quantity and temperature settings
You can set air flow of supply and exhaust air, desired temperature and turn off/on an electric heater for each ventilation
mode. If turned off, the heater will not turn on even when the desired temperature is not reached. If turned on, the heater will
operate only when the heat exchanger alone cannot reach the set temperature. Press “Modify” to modify operation mode
settings. After changing the settings, press “Save changes” button at the bottom of the window. Press the return symbol at
the top to return to the main window.
CONTROL
OPERATION MODES
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
64
64
20.0
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
160
160
20.0
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
210
210
20.0
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
Activate by contact
Delayed start, min
Delayed stop, min
260
260
20.0
0
0
All time
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
190
160
20.0
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
260
64
20.0
Temperature, °C
Electric heater
Micro-ventilation
Period
20.0
4 t. per day
2018-12-24 / 2019-01-02
Supply flow, m³/h
Extract flow, m³/h
Temperature, °C
Electric heater
300
300
20.0
SAVE CHANGES
RESTORE TO DEFAULT
INTENSIVE
NORMAL
AWAY
BOOST
HOLIDAYS
KITCHEN
OVERRIDE
FIREPLACE