METHOD FOR DRAINING THE HYDRAULIC OIL TANK ....................................................................... 4-55
METHOD FOR CLEANING THE ELECTRIC COMMUTATOR OF THE ROTATING JOINT .................... 4-57
METHOD FOR CHECKING THE BRAKE ACCUMULATOR PRECHARGE PRESSURE........................ 4-58
EVERY 1000 HOURS MAINTENANCE ......................................................................................................... 4-59
METHOD FOR CHECKING THE BRAKING PRESSURE ....................................................................... 4-59
METHOD FOR REPLACING HYDRAULIC OIL FILTER ELEMENT........................................................ 4-59
METHOD FOR CHANGE OIL IN SWING MACHINERY CASE ............................................................... 4-61
METHOD FOR CHANGING THE OIL IN THE TRANSMISSION REDUCTION GEAR............................ 4-61
METHOD FOR CHANGING THE FRONT AXLE OIL .............................................................................. 4-62
METHOD FOR CHANGING THE REAR AXLE OIL ................................................................................ 4-63
METHOD FOR ADJUSTING THE PARKING BRAKE ............................................................................. 4-64
METHOD FOR CHECKING OIL LEVEL IN PTO GEAR CASE, ADDING OIL ......................................... 4-64
METHOD FOR REPLACING FUEL MAIN FILTER CARTRIDGE ............................................................ 4-65
METHOD FOR CHECKING ALL TIGHTENING POINTS OF ENGINE INTAKE PIPE CLAMPS.............. 4-67
METHOD FOR CHECKING FAN BELT TENSION AND REPLACING FAN BELT ................................... 4-67
EVERY 2000 HOURS MAINTENANCE ......................................................................................................... 4-67
METHOD FOR CHANGING OIL IN HYDRAULIC TANK, CLEANING HYDRAULIC TANK STRAINER... 4-68
METHOD FOR CHECKING AND RELEASING NITROGEN GAS CHARGE PRESSURE IN ACCUMULA-
TORS (FOR CONTROL CIRCUIT) ...................................................................................................... 4-71
METHOD FOR CHECKING ALTERNATOR AND STARTING MOTOR ................................................... 4-75
METHOD FOR CHECKING AND ADJUSTING ENGINE VALVE CLEARANCE ...................................... 4-75
METHOD FOR REPLACING KCCV FILTER ELEMENT ......................................................................... 4-75
EVERY 4000 HOURS MAINTENANCE ......................................................................................................... 4-78
REPLACE DEFINED LIFE PARTS.......................................................................................................... 4-78
METHOD FOR CHECKING WATER PUMP............................................................................................ 4-79
METHOD FOR REPLACING ACCUMULATORS (FOR CONTROL CIRCUIT)........................................ 4-79
METHOD FOR CHECKING FOR LOOSENESS OF ENGINE HIGH-PRESSURE PIPING CLAMP, HARD-
ENING OF RUBBER ........................................................................................................................... 4-80
METHOD FOR CHECKING FOR MISSING FUEL SPRAY PREVENTION CAP, HARDENING OF RUBBER.
............................................................................................................................................................ 4-80
EVERY 5000 HOURS MAINTENANCE ......................................................................................................... 4-80
METHOD FOR CHANGING OIL IN HYDRAULIC TANK, CLEANING HYDRAULIC TANK STRAINER... 4-81
MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER
For machine equipped with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket dig-
ging operations, so set the maintenance intervals as follows.
Replace hydraulic filter element
On a new machine, replace the element after the first 100 to
150 hours, then perform further replacement of the element ac-
cording to the table.
Change oil in hydraulic tank
Change the oil according to the table.
Replace additional filter element for breaker (if equip-
ped)
Use a guideline of 250 hours for use of the breaker (operating
ratio of the breaker: 50% or more), and replace the element ac-
cording to the table.
X: Breaker operating ratio (%)
Y: Replacement interval (H)
(A):Element of hydraulic tank
(B):Hydraulic oil
(C):Element of additional filter
MAINTENANCE
MAINTENANCE SCHEDULE TABLE
4-11
WENAM00061
Содержание PW98MR-10
Страница 1: ......
Страница 2: ......
Страница 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 7 WENAM00061...
Страница 35: ...21 Lock front window 22P 00 11381 22 Lifting decal 21D 00 41170 SAFETY SAFETY LABELS 2 15 WENAM00061...
Страница 68: ...WENAM00061...
Страница 70: ...GENERAL VIEW MACHINE EQUIPMENT NAME 1 Bucket cylinder 2 Arm GENERAL VIEW OPERATION 3 2 WENAM00061...
Страница 73: ...CONTROLS AND GAUGES NAMES OPERATION GENERAL VIEW 3 5 WENAM00061...
Страница 157: ...SWITCHES OPERATION EXPLANATION OF COMPONENTS 3 89 WENAM00061...
Страница 305: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 WENAM00061...
Страница 388: ...WENAM00061...
Страница 389: ...SPECIFICATIONS 5 1 WENAM00061...
Страница 392: ...RKA55390 SPECIFICATIONS SPECIFICATIONS 5 4 WENAM00061...
Страница 402: ...WENAM00061...
Страница 428: ...WENAM00061...
Страница 429: ...REPLACEMENT PARTS 7 1 WENAM00061...
Страница 444: ...F10003 WHEELED EXCAVATOR Form No WENAM00061 2016 KOMATSU All Rights Reserved Printed in Japan 07 2016 WENAM00061...
Страница 445: ......
Страница 446: ......