Connection
Hold the tightening adapter part, and push body (2) straight un-
til sliding prevention ring (1) contacts contact surface (a) of the
hexagonal part at the male end.
METHOD FOR DISCONNECTING AND CONNECTING TYPE 3 PUSH-PULL TYPE
COUPLER
Disconnection
1.
Hold the tightening adapter part and push body (2) straight
until sliding prevention ring (1) contacts contact surface (a)
of the hexagonal part at the male end.
2.
While keeping the condition of step 1, push cover (3)
straight until it contacts contact surface (a) of the hexago-
nal portion on the male side.
3.
While keeping the conditions of steps 1 and 2, pull out
whole body (2) to disconnect it.
REMARK
Provide an container to receive a quantity of hydraulic oil
which may flow out.