MAINTENANCE
SERVICE PROCEDURE
REPLACING INNER ELEMENT
1. First remove the cover and the outer element, and then remove the inner element.
2. Cover the air connector side (outlet side) with a clean cloth or tape.
3. Clean the air cleaner body interior, then remove the cover installed in Step 2.
4. Install a new inner element to the body.
Do not clean and re-use an inner element.
5. Install the outer element and the cover.
6. Remove evacuator valve (4) and clean it with compressed air. After cleaning, install it again.
7. After replacing the element, return the red line of the dust indicator to its original position.