MAINTENANCE
MAINTENANCE PROCEDURE
BLEEDING AIR FROM HYDRAULIC SYSTEM
NOTICE
If the pump is operated without filling the pump case with hydraulic oil, there is danger that the pump may be prematurely
damaged. Be sure to bleed the air completely.
1. Bleeding air from piston pump
1) Remove bolts (1) (M10 x 3), then remove triangular cover
(2).
2) Remove the oil filler cap from the hydraulic oil tank.
3) Loosen air bleed plug (3) and check that oil oozes out from the bleeder plug (completion of air bleeding).
PC27MR
PC35MR
4) After completion of the air bleeding operation, tighten the air bleed plug.
5) Tighten the oil filler cap of the hydraylic oil tank.
6) Install the cover.
2. Start the engine. For details, see "STARTING ENGINE (PAGE 3-54)".
Run the engine at low idle for 10 minutes, then do as follows.