SERVICE INTERVALS
MAINTENANCE SCHEDULE -
Pressuriser
DAILY INSPECTION
Component / System
Inspection Required
Pre-cleaner - Dust Bowl
If fitted with a Dust Bowl Pre-cleaner, remove
from the pressuriser unit, clean and refit.
MONTHLY INSPECTION
Component / System
Inspection Required
Pre-cleaner - Turbo
If fitted, check operation of Turbo pre cleaner.
Filter Element
Remove internal filter element and while up-
side down, hit firmly on a flat surface. Repeat
procedure several times or replace element as
required.
Filter Housing
Check the lid seals and all bolt and screws are
secure.
THREE MONTHLY INSPECTION
Component / System
Inspection Required
Filter Element
Replace the filter element.
Fan
Check the fan wheel is operating correctly.
Filter Housing
Vacuum out and clean all internal surfaces of
dust.
4000 HOURS INSPECTION
Component / System
Inspection Required
Filter Element
Replace the filter element.
Fan
Replace Pressuriser Fans
Filter Housing
Vacuum out and clean all internal surfaces of
dust.
Mounting
Check all mountings.