Connection
Hold the tightening adapter part, and push body (2) straight un-
til sliding prevention ring (1) contacts contact surface (a) of the
hexagonal part at the male end.
METHOD FOR DISCONNECTING AND CONNECTING TYPE 3 PUSH-PULL TYPE
COUPLER
Disconnection
1.
Hold the tightening adapter part and push body (2) straight
until sliding prevention ring (1) contacts contact surface (a)
of the hexagonal part at the male end.
2.
While keeping the condition of step 1, push cover (3)
straight until it contacts contact surface (a) of the hexago-
nal portion on the male side.
3.
While keeping the conditions of steps 1 and 2, pull out
whole body (2) to disconnect it.
REMARK
Provide an container to receive a quantity of hydraulic oil
which may flow out.
DISCONNECT AND CONNECT PUSH-PULL TYPE COUPLER
00 INDEX AND FOREWORD
00-56
PC210LC-11
Содержание 500001
Страница 1: ...HYDRAULIC EXCAVATOR SEN06516 01 PC210LC 11 SERIAL NUMBERS 500001 and up ...
Страница 2: ...Find manuals at https best manuals com ...
Страница 3: ...00 INDEX AND FOREWORD PC210LC 11 00 1 Find manuals at https best manuals com ...
Страница 61: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...