14.2
Connection of the motors with preassembled cables
—
Carry out the wiring in accordance with the valid standards and regulations.
—
Only use Kollmorgen preassembled shielded cables for the resolver and power con-
nections.
—
Incorrectly installed shielding leads to EMC interference and has an adverse effect
on system function.
—
The maximum cable length is defined in the instructions manual of the used servo
amplifier.
For a detailed description of preassembled cables, please refer to the accessories
manual.
14.3
Guide for electrical installation
—
Check that the servo amplifier and motor match each other. Compare the rated vol-
tage and rated current of the unit. Carry out the wiring according to the wiring dia-
gram in the instructions manual of the servo amplifier. The connections to the motor
are shown in chapter "Connector Pinout" from p.72.
—
Install all cables carrying a heavy current with an adequate cross-section, as per EN
60204. The recommended cross-section can be found in the Technical data.
In case of long motor cables (>25m) and dependent on the type of the used servo ampli-
fier a motor choke (3YL or 3YLN) must be switched into the motor cable (see instructions
manual of the servo amplifier and accessory manual).
—
Ensure that there is proper earthing of the servo amplifier and the motor. Use correct
earthing and EMC-shielding according to the instructions manual of the servo ampli-
fier which is used. Earth the mounting plate and motor casing.
—
Cabling:
—
Route power cables as separately as possible from control cables
—
Connect up the resolver or encoder.
—
Connect the motor cables, install motor chokes close to the amplifier
Connect shields to shielding terminals or EMC connectors at both ends
—
Connect up all shielding via a wide surface-area contact (low impedance) and me-
tallized connector housings or EMC-cable glands.
—
Requirements to cable material:
Capacity
Motor cable
less than 150 pF/m
Resolver cable
less than 120 pF/m
Servomotors VLM
English - 33
Kollmorgen
01/2013
Electrical Installation
ENGLISH
Содержание VLM Series
Страница 8: ...Diese Seite wurde bewusst leer gelassen Deutsch 8 Servomotoren VLM 01 2013 Kollmorgen DEUTSCH...
Страница 65: ...This page has been deliberately left blank Servomotors VLM General 65 Kollmorgen 01 2013 Datos t cnicos...
Страница 77: ...36 2 EC Declaration of Conformity Servomotors VLM General 77 Kollmorgen 01 2013 Approvals...