4.5
External regen resistor (X0), master only
Remove the plug-on link between terminals X0/5 (-R
B
) and X0/4 (+R
bint
).
4.6
Feedback
4.6.1
Resolver connection (X5)
Our rotary servomotors have 2-pole hollow-shaft resolvers built in as a standard.
It is possible to connect 2- to 32-pole resolvers to SERVOSTAR 400. If lead lengths of
more than 25m are planned, please consult our customer support.
The thermostat contact in the motor is connected via the resolver cable to the
SERVOSTAR 400 and evaluated there.
SERVO
STAR
®
400 Installation Manual
39
Kollmorgen
07/05
Interfaces
SERVOSTAR 400
SERVOSTAR 400
SubD9
12-pin round