3.142
IDN278 Maximum Traverse
Data Length: 4 bytes
Non-Volatile:
Yes
Data Type:
Unsigned decimal
Write Access:
CP2, CP3, CP4
Minimum:
0 or Module value, if active
Run-Up Check:
Maximum:
2
31
- 1
Cyclic Transfer:
Default:
0
ASCII Param.:
SWE2
3.143
IDN288 IDN List of Data Programmable in CP2
A list of all IDNs that may be written by the master in CP2. The IDNs are listed in the
order in which the master should write them to avoid data dependency problems. Data
dependency problems may arise, for example, when the range of one IDN depends upon
an IDN that has not yet been written.
Data Length:
2 byte elements, variable
length array
Non-Volatile:
Fix
Data Type:
IDN
Write Access:
Read-only
Minimum:
Run-Up Check:
Maximum:
Cyclic Transfer:
Default:
ASCII Param.:
3.144
IDN289 IDN List of Data Programmable in CP3
A list of all IDNs that may be written by the master in CP3. The IDNs are listed in the
order in which the master should write them to avoid data dependency problems. Data
dependency problems may arise, for example, when the range of one IDN depends upon
an IDN that has not yet been written.
Data Length:
2 byte elements, variable
length array
Non-Volatile:
Fix
Data Type:
IDN
Write Access:
Read-only
Minimum:
Run-Up Check:
Maximum:
Cyclic Transfer:
Default:
ASCII Param.:
3.145
IDN290 Device Type
Neccessary information for some master controls.
Data Length: 2 bytes
Non-Volatile:
Fix
Data Type:
Unsigned decimal
Write Access:
read-only
Minimum:
0
Run-Up Check:
Maximum:
0
Cyclic Transfer:
Default:
0
ASCII Param.:
sercos
®
for S300/S700
73
Kollmorgen
04/2016
sercos
®
IDN Set