EB-60X Installation & Service Manual |
Wiring
Use a Corcom 5R1 single phase filter or equivalent (for CE
requirements).
Use a Shaffner three phase filter or equivalent
•
Model No. 258-16/07 for PSR4/5A-112 & 212.
•
Model No. 258-30/77 for PSR4/5A-120 & 220.
•
Model No. 258-55/07 for PSR4/5A-250.
•
Model No. 258-75/34 for PSR4/5A-275.
•
For CE requirements.
Use a Shaffner three phase choke or equivalent.
•
Model No. RD 7137-6-12m0 or RD 7137-36-0m5 for BDS4A-103,
203, 106 & 206.
•
Model No. RD 7137-10-6m6 or RD 7137-36-0m5 for BDS4A-110 &
210
•
Model No. RD 7137-25-1m3 or RD 7137-36-0m5 for BDS4A-120
&220
•
Model No. RD 7137-36-12m0 for BDS4A-230.
•
Model No. RD 7137-64-12m0 BDS4A-240 & 255.
•
(For CE requirements)
Suitable for use on circuit capable of delivering not more than 5000
symmetrical A
RMS
, 240 volts max.