5.3.60 Object 6071h: Target torque (DS402)
This parameter is the input value for the torque controller in profile torque mode and the value
is given per thousand (1‰) of rated torque.
Index
6071h
Name
Target torque
Object code
VAR
Data type
INTEGER16
Category
conditional; mandatory, if tq supported
Access
R/W
PDO mapping
possible
Value range
INTEGER16
Default value
0
5.3.61 Object 6073h: Max current (DS402)
This value represents the maximum permissible torque creating current in the motor and is
given per thousand (1‰) of rated current.
Index
6073h
Name
Max current
Object code
VAR
Data type
UNSIGNED16
Category
optional
Access
R/W
PDO mapping
not possible
Value range
UNSIGNED16
Default value
0
5.3.62 Object 6077h: Torque actual value (DS402)
The torque actual value corresponds to the instantaneous torque in the drive motor. The
value is given per thousand (1‰) of rated torque. This object reflects the actual current
(DRV.ICONT).
Index
6077h
Name
Torque actual value
Object code
VAR
Data type
INTEGER16
Category
optional
Access
R/O
PDO mapping
possible
Value range
INTEGER16
Default value
0
AKD EtherCAT | 5 Appendix
Kollmorgen | kdn.kollmorgen.com | October 2017
139