Owner’s Manual
6KK14BEA2AA00 / 6KK17BGA2AA00 / 6KK21BGA2AA00
1
Owner’s Manual
WPC-3000, WPC-4000, WPC-5000
Owner’s Manual
6KK14BEA2AA00 / 6KK17BGA2AA00 / 6KK21BGA2AA00
Please read and save these instructions. Read carefully before attempting to assemble, install, oper-
ate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and / or property damage! Retain instructions for future reference.
Koldwave Portable Air Conditi oners feature spot cooling for
large areas where cooling of the enti re area is not practi cal.
A dedicated spot cooling thermostat controls the unit in this
applicati on.
These air conditi oners can also be used in smaller areas for
room cooling. A control panel provides ease of use and con-
tains a self-diagnosti c functi on and display, showing operat-
ing modes, room and set temperatures, and faults.
If an abnormal operati on occurs, a visual display of the fault
is shown. Caster wheels are included for easy portability.
Suitable applicati ons include: a factory or work place, indus-
trial kitchen, computer room, emergency cooling, outdoor
event, etc.
Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during
transit. Check for any loose, missing, or damaged parts.
Descripti on
Unpacking
6KK14BEA2AA00, 6KK17BGA2AA00,
6KK21BGA2AA00
Figure 1
Specifi cati ons
Model No.
Power Supply Ph-V-Hz
Cooling Capac-
ity Btu/h
Power Con-
sumpti on Watt s
Rated Cur-
rent Amps
EER Btu/
Wh
6KK14BEA2AA00
Single Phase, 115V, 60Hz
13,200
1300
11.9
11.0
6KK17BGA2AA00 Single Phase, 115V, 60Hz
16,800
1700
15.5
9.8
6KK21BGA2AA00 Single Phase, 208/230V, 60Hz
21,200
2400
11.3 / 10.9
8.8
Model No.
Nema Plug
Power Cord
Gauge AWG
Power Cord
Length ft
Dimensions
W x D x H - in. (mm)
6KK14BEA2AA00
5-15P
14
10
20.6 x 26.4 x 41
(523 x 671 x 1042)
6KK17BGA2AA00
5-20P
12
6
6KK21BGA2AA00
6-15P
14
10
Portable Air Conditioners